346638356
|
1032100
|
2023-04-11
|
AML DOCK, JUNEAU, AK, 99801
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2023-04-11
|
Case Closed |
2023-05-11
|
|
341721223
|
1050210
|
2016-08-03
|
202 INDUSTRY WAY, CORDOVA, AK, 99574
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Emphasis |
S: TRANSPORTATION/WAREHOUSIN, P: HHT, S: HHT
|
|
340696541
|
1032100
|
2015-06-10
|
AML MARINE FACILITY, CORDOVA, AK, 99574
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Health
|
Close Conference |
2015-06-10
|
Emphasis |
L: LONGSHORE, P: LONGSHORE
|
Case Closed |
2015-07-31
|
Related Activity
Type |
Inspection |
Activity Nr |
1069660 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19180104 A |
Issuance Date |
2015-06-24 |
Abatement Due Date |
2015-07-28 |
Current Penalty |
2125.0 |
Initial Penalty |
4250.0 |
Final Order |
2015-07-22 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1918.104(a): The employer did not ensure that each affected employee wore protective footwear when working in areas where there was a danger of foot injuries due to falling or rolling objects or objects piercing the sole: Cordova Terminal, Cordova Provider: On or about June 10, 2015 and at times prior thereto, employees exposed to foot injury hazards were not required to wear protective footwear. Employees were observed wearing athletic footwear in work areas where footwear in areas where foot injuries could occur. This condition exposed employees to foot injuries. |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19170093 A |
Issuance Date |
2015-06-24 |
Abatement Due Date |
2015-07-28 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2015-07-22 |
Nr Instances |
1 |
Nr Exposed |
4 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1917.93(a): The employer did not ensure that employees exposed to falling objects wore protective helmets: Cordova Terminal, Cordova Provider: On or about June 10, 2015 and at times prior thereto, employees working in the vicinity of overhead loads and falling objects were not wearing protective helmets. This condition exposed employees to struck-by hazards. |
|
Citation ID |
01001C |
Citaton Type |
Serious |
Standard Cited |
19170071 E |
Issuance Date |
2015-06-24 |
Abatement Due Date |
2015-07-28 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2015-07-22 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1917.71(e): Employees working in the immediate area of container handling equipment or in the terminal's traffic lanes were not wearing high visibility vests, decals, reflectors or equivalent protection. Cordova Terminal, Cordova Provider: On or about June 10, 2015 and at times prior thereto, employee was observed not wearing protection that provided retro-reflective materials. This condition exposed employees to struck-by hazards. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19170071 J02 |
Issuance Date |
2015-06-24 |
Abatement Due Date |
2015-07-28 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2015-07-22 |
Nr Instances |
1 |
Nr Exposed |
4 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1917.71(j)(2): The employer did not develop, implement, and maintain a written plan for transporting vertically connected containers: Cordova Terminal, Cordova Provider: On or about June 10, 2015 and at times prior thereto, a written plan regarding the transportation of containers as a vertical tandem lift had not been developed, implemented, or maintained. This condition exposed employees to limited information on the hazards of performing this work activity. |
|
Citation ID |
02002 |
Citaton Type |
Other |
Standard Cited |
19101200 F06 II |
Issuance Date |
2015-06-24 |
Abatement Due Date |
2015-07-28 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2015-07-22 |
Nr Instances |
1 |
Nr Exposed |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(f)(6)(ii): Except as provided in 29 CFR 1910.1200(f)(7) and 29 CFR 1910.1200(f)(8), the employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the product identifier and words, pictures, symbols, or combination thereof, which provide at least general information regarding the hazards of the chemicals and which, in conjunction with the other information immediately available to employees under the hazard communication program, would provide employees with the specific information regarding the physical and health hazards of the hazardous chemical: Maintenance Shop: On or about June 10, 2015 and at times prior thereto, an unlabeled spray bottle container with unknown contents was found on the maintenance work bench. This condition limited employee information on the contents of the container and the proper safety and health controls necessary when using the product. |
|
|
340696608
|
1032100
|
2015-06-10
|
AML MARINE FACILITY, CORDOVA, AK, 99574
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2015-06-10
|
Emphasis |
L: LONGSHORE, P: LONGSHORE
|
Case Closed |
2015-07-31
|
Related Activity
Type |
Inspection |
Activity Nr |
1069654 |
Health |
Yes |
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19100303 G01 II |
Issuance Date |
2015-06-24 |
Abatement Due Date |
2015-07-28 |
Current Penalty |
1275.0 |
Initial Penalty |
2550.0 |
Final Order |
2015-07-22 |
Nr Instances |
1 |
Nr Exposed |
7 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.303(g)(1)(ii): The required working space about electric equipment rated 600 volts, nominal, or less to ground, was used for storage. Attic storage area; on or about 10 June 2015 and times prior thereto; three propane cylinders were stored in front of the electrical panel in the garage bay area. This condition exposed employees to an electrical shock and electrical burn hazard. |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19100303 G02 II |
Issuance Date |
2015-06-24 |
Abatement Due Date |
2015-07-28 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2015-07-22 |
Nr Instances |
1 |
Nr Exposed |
7 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.303(g)(2)(ii): In locations where electric equipment was likely to be exposed to physical damage, enclosures or guards were not so arranged and of such strength as to prevent such damage. Attic storage area; on or about 10 June 2015 and times prior thereto; Three incandescent light fixtures located 56 inches from the floor were not guarded. This condition exposed employees to an electrical shock and electrical burn hazard. |
|
Citation ID |
01001C |
Citaton Type |
Serious |
Standard Cited |
19100305 B01 II |
Issuance Date |
2015-06-24 |
Abatement Due Date |
2015-07-28 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2015-07-22 |
Nr Instances |
1 |
Nr Exposed |
7 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed. Garage bay, adjacent to office access; on or about 10 June 2015 and times prior thereto; A knockout plug was missing from a 240 volt energized electrical receptacle. This condition exposed employees to electrical shock and electrical burn hazard. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19170112 E |
Issuance Date |
2015-06-24 |
Abatement Due Date |
2015-07-28 |
Current Penalty |
1275.0 |
Initial Penalty |
2550.0 |
Final Order |
2015-07-22 |
Nr Instances |
1 |
Nr Exposed |
7 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1917.112(e): Railings and mid rails were not provided at any stairway having four or more risers. Garage bay, attic access; on or about 10 June 2015 and times prior thereto; A mid rail was not provided on a stair way with eight risers. Stairs are used to access a storage area in located the attic. This condition exposed employees to a fall hazard. |
|
|
339780322
|
1032100
|
2014-05-21
|
110 OSCAR, BETHEL, AK, 99559
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2014-05-21
|
Emphasis |
L: LONGSHORE, P: LONGSHORE
|
Case Closed |
2014-07-01
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19170043 C05 |
Issuance Date |
2014-05-28 |
Abatement Due Date |
2014-06-11 |
Current Penalty |
1530.0 |
Initial Penalty |
3060.0 |
Final Order |
2014-06-18 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1917.43(c)(5): Safety devices on powered industrial trucks were removed or made inoperative: Warehouse: On or about May 21, 2014 and at times prior thereto, the seat belt on the Mitsubishi model number FG25N, serial number AF17D02105, equipment number 546 was inoperative. (1) The seatbelt was routed in front of the seat and attached to the clasp. (2) The retraction device was not operative. This condition exposed employee to caught-between hazards in the event of a rollover incident. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19170154 |
Issuance Date |
2014-05-28 |
Current Penalty |
1912.5 |
Initial Penalty |
3825.0 |
Final Order |
2014-06-18 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1917.154: Compressed air for cleaning exceeded 30 psig: Warehouse: On or about May 21, 2014 and at times prior thereto, compressed air for cleaning measured 120 psig at the compressor and 50 psig at the shop-made nozzle tip. This condition exposed employees to injection and air embolism hazards in the event of contact with broken skin. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19100305 G01 IV A |
Issuance Date |
2014-05-28 |
Abatement Due Date |
2014-06-11 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2014-06-18 |
Nr Instances |
1 |
Nr Exposed |
4 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: Warehouse: North Wall, Mobile Radio Power: On or about May 21, 2014 and at times prior thereto, a flexible cord was used as a substitute for fixed wiring. The flexible cord was routed up the north wall and across and wrapped around roof joists to a 120 volt outlet on the west wall. This condition exposed employees to minor smoke-inhalation injuries in the event of fire from flexible cord failure. |
|
|
18165381
|
1032100
|
1999-01-26
|
100 MT. ROBERTS, JUNEAU, AK, 99802
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
1999-01-26
|
Case Closed |
1999-02-11
|
|