345273585
|
1032100
|
2021-04-27
|
SEAFREEZE AMERICA, DUTCH HARBOR, AK, 99692
|
|
Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Health
|
Close Conference |
2021-09-30
|
Emphasis |
L: FISH, N: COVID-19
|
Case Closed |
2021-10-06
|
Related Activity
Type |
Complaint |
Activity Nr |
1756927 |
Health |
Yes |
|
|
343866364
|
1032100
|
2019-03-21
|
C/P SEAFREEZE AMERICA CAPTAIN'S BAY, DUTCH HARBOR, AK, 99692
|
|
Inspection Type |
Referral
|
Scope |
NoInspection
|
Safety/Health |
Safety
|
Emphasis |
L: FISH
|
Case Closed |
2019-04-05
|
Related Activity
Type |
Referral |
Activity Nr |
1437885 |
Safety |
Yes |
|
|
342944477
|
1032100
|
2018-02-07
|
F/T SEAFREEZE ALASKA OSI DOCK, DUTCH HARBOR, AK, 99692
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Health
|
Close Conference |
2018-02-07
|
Emphasis |
L: FISH, P: FISH
|
Case Closed |
2018-07-13
|
Related Activity
Type |
Inspection |
Activity Nr |
1294457 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100151 C |
Issuance Date |
2018-03-22 |
Abatement Due Date |
2018-04-12 |
Current Penalty |
3000.0 |
Initial Penalty |
4366.0 |
Final Order |
2018-04-16 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use: Factory Deck: On or about February 7, 2018 and at times prior thereto, facilities were not available for employees that mixed the corrosive all purpose concentrated cleaner "Red Hot." This condition exposed employees to eye injuries. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19151026 D04 I |
Issuance Date |
2018-03-22 |
Abatement Due Date |
2018-04-12 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2018-04-16 |
Nr Instances |
1 |
Nr Exposed |
2 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1915.1026(d)(4)(i): Within 5 working days after making an exposure determination the employer did not individually notify the employee in writing of the results of the of that determination or post the results in an appropriate location accessible to all affected employees: Factory Deck: On or about February 7, 2018 and at times prior thereto, the employer had not notified employees required to perform hotwork on stainless steel processing equipment on the exposure determination. This condition limited employee information on the their exposure to Chromium (VI) hazards. |
|
|
342944576
|
1032100
|
2018-02-07
|
F/T SEAFREEZE ALASKA OSI DOCK, DUTCH HARBOR, AK, 99692
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2018-02-07
|
Emphasis |
P: FISH, L: FISH
|
Case Closed |
2018-08-20
|
Related Activity
Type |
Inspection |
Activity Nr |
1294447 |
Health |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19180032 B |
Issuance Date |
2018-03-22 |
Abatement Due Date |
2018-04-12 |
Current Penalty |
4434.0 |
Initial Penalty |
5543.0 |
Final Order |
2018-08-16 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1918.32(b): The edge of a hatch section, or of stowed cargo, was not guarded by a vertical safety net or other means providing equal fall protection to exposed employees. (a) Offload hatch: On or about February 7, 2018 and times prior thereto, a two foot section of the hatch was not guarded when employees worked in the area. This exposed employee to a 10 foot fall to the freezer section. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19180062 G02 III |
Issuance Date |
2018-03-22 |
Abatement Due Date |
2018-04-12 |
Current Penalty |
3326.0 |
Initial Penalty |
4158.0 |
Final Order |
2018-08-16 |
Nr Instances |
1 |
Nr Exposed |
20 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1918.62(g)(2)(iii): Synthetic web slings were not removed from service when they exhibited snags, punctures, tears, or cuts. Freezer section: On or about February 7, 2018 and times prior thereto, one leg on a brailer bag had tear half way through the synthetic sling. This exposed employees to struck-by hazard it the sling broke while off loading fish product. |
|
|
342941887
|
1032100
|
2018-02-06
|
F/V VAERDAL CROWLEY DOCK, DUTCH HARBOR, AK, 99692
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Health
|
Close Conference |
2018-02-06
|
Emphasis |
L: FISH, P: FISH
|
Case Closed |
2018-03-13
|
Related Activity
Type |
Inspection |
Activity Nr |
1294184 |
Safety |
Yes |
|
|
342941846
|
1032100
|
2018-02-06
|
F/V VAERDAL CROWLEY DOCK, DUTCH HARBOR, AK, 99692
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2018-02-06
|
Emphasis |
L: FISH, P: FISH
|
Case Closed |
2018-04-17
|
Related Activity
Type |
Inspection |
Activity Nr |
1294188 |
Health |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Other |
Standard Cited |
19150089 B |
Issuance Date |
2018-03-13 |
Abatement Due Date |
2018-04-10 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2018-04-10 |
Nr Instances |
1 |
Nr Exposed |
2 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1915.89(b): The employer did not establish and implement a written program and procedures for lockout and tags-plus systems to control hazardous energy during the servicing of any machinery, equipment, or system in shipyard employment. F/V Vaerdal, Crowley Dock, Engine Room; on or about 06 February 2018 and times prior thereto; the employers written lockout/tagout program was not in accordance with the Shipyard standard for lockout/tags systems. Employer was using the General Industry standard 1910.147. This condition exposed employees to inadequate work standards. |
|
|
342167244
|
1032100
|
2017-03-08
|
F/T LEGACY CROWLEY DOCK, DUTCH HARBOR, AK, 99692
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Health
|
Close Conference |
2017-03-08
|
Emphasis |
L: FISH, P: FISH
|
Case Closed |
2017-03-16
|
Related Activity
Type |
Inspection |
Activity Nr |
1216720 |
Safety |
Yes |
|
|
342167202
|
1032100
|
2017-03-08
|
F/T LEGACY CROWLEY DOCK, DUTCH HARBOR, AK, 99692
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2017-03-08
|
Emphasis |
L: FISH, P: FISH
|
Case Closed |
2017-04-12
|
Related Activity
Type |
Inspection |
Activity Nr |
1216724 |
Health |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Other |
Standard Cited |
19150089 Q01 |
Issuance Date |
2017-03-16 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2017-04-12 |
Nr Instances |
1 |
Nr Exposed |
2 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1915.89(q)(1): The employer did not ensure that the audit was performed by an authorized employee other than the one(s) currently using the energy-control procedure being reviewed. F/T Legacy: On or about 8 March 2017 and times prior thereto, the Annual Audit of hazardous energy (lockout/tags-plus) program was not accomplished. Last documented annual audit was accomplished in 15 January 2012. |
|
|
340417500
|
1032100
|
2015-02-11
|
F/T LEGACY CITY DOCK, DUTCH HARBOR, AK, 99692
|
|
Inspection Type |
Planned
|
Scope |
Records
|
Safety/Health |
Safety
|
Close Conference |
2015-02-11
|
Emphasis |
L: FISH, P: FISH
|
Case Closed |
2015-04-02
|
|
338910763
|
1032100
|
2013-02-12
|
F/T VAERDAL CROWLEY DOCK, DUTCH HARBOR, AK, 99692
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Health
|
Close Conference |
2013-02-12
|
Emphasis |
L: FISH, N: AMPUTATE, P: FISH
|
Case Closed |
2013-05-15
|
Related Activity
Type |
Inspection |
Activity Nr |
891074 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100132 D01 I |
Issuance Date |
2013-03-11 |
Abatement Due Date |
2013-03-28 |
Current Penalty |
2550.0 |
Initial Penalty |
2550.0 |
Final Order |
2013-05-09 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.132(d)(1)(i): The employer did not select and have each affected employee use, the types of personal protective equipment that would protect the affected employee(s) from the hazards identified in the hazard assessment: Galley: On or aobut 2/12/2013, the cook did not have nor was required to use cut resistant gloves while using knives in the galley for food preparation. This condition exposed the employee to laceration hazards. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19040032 A01 |
Issuance Date |
2013-03-11 |
Abatement Due Date |
2013-03-28 |
Current Penalty |
0.0 |
Initial Penalty |
850.0 |
Final Order |
2013-05-09 |
Nr Instances |
2 |
Nr Exposed |
23 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1904.32(a)(1): The employer did not review the OSHA 300 Log to verify that the entries are complete and accurate, and correct any deficiencies identified: F/T Vaerdal: On or about 2/12/2013, the OSHA 300 logs for calendar year 2012 were reviewed and were not equal to the OSHA 300A posted in the vessel: (a) A lost work injury which occurred on 6/24/2012 where an employee was injured and could not work for 4 days was not in the OSHA 300A summary. (b) The summary posted on the OSHA 300A reflected 6 injuries with no lost time, while the OSHA 300 log showed 1 other recordable injury and 1 recordable lost time injury. |
|
|
338910748
|
1032100
|
2013-02-12
|
F/T VAERDAL CROWLEY DOCK, DUTCH HARBOR, AK, 99692
|
|
Inspection Type |
Planned |
Scope |
Complete |
Safety/Health |
Safety |
Close Conference |
2013-02-12 |
Emphasis |
N: AMPUTATE, L: FISH, P: FISH |
Case Closed |
2013-05-15 |
Related Activity
Type |
Inspection |
Activity Nr |
891076 |
Health |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100212 A01 |
Issuance Date |
2013-03-11 |
Abatement Due Date |
2013-04-11 |
Current Penalty |
1530.0 |
Initial Penalty |
2550.0 |
Final Order |
2013-05-09 |
Nr Instances |
2 |
Nr Exposed |
1 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks. (a) Galley Area: On or about 12 February 2013 and times prior thereto, the Dayton galley freezer fan did not have a guard installed. This condition exposed employees to a caught in hazard. (b) Food Storage Area: On or about 12 February 2013 and times prior thereto, the Dayton fan in the storage room did not have a guard installed. This condition exposed employees to a caught in hazard. |
|
|
338910433
|
1032100
|
2013-02-10
|
F/T SEAFREEZE ALASKA OSI DOCK, DUTCH HARBOR, AK, 99692
|
|
Inspection Type |
Planned |
Scope |
Complete |
Safety/Health |
Health |
Close Conference |
2013-02-10 |
Emphasis |
L: FISH, N: AMPUTATE, P: FISH |
Case Closed |
2013-05-15 |
Related Activity
Type |
Inspection |
Activity Nr |
891036 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19150089 E04 |
Issuance Date |
2013-03-11 |
Abatement Due Date |
2013-04-04 |
Current Penalty |
0.0 |
Initial Penalty |
2550.0 |
Final Order |
2013-05-09 |
Nr Instances |
1 |
Nr Exposed |
7 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1915.89(e)(4): The employer shall ensure that the authorized employee relieves, disconnects, restrains, or otherwise renders safe all potentially hazardous energy that is connected to the machinery, equipment, or system. F/T Seafreeze (Factory): On or about 2/10/2013, and times prior thereto, an employee was working on the Pan Conveyor without ensuring that all energy sources were rendered safe by turning off the hydraulic disconnect on the equipment and tagging it as de-energized; exposing employees to caught in hazards. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100242 B |
Issuance Date |
2013-03-11 |
Current Penalty |
2550.0 |
Initial Penalty |
2550.0 |
Final Order |
2013-05-09 |
Nr Instances |
1 |
Nr Exposed |
5 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.: F/T Seafreeze Alaska (Engine Room): On or abouot 2/10/2013, and times prior thereto, an air nozzle was used for cleaning purposes that measured over 85 psi without reduction; exposing employees to a laceration hazard. |
|
|
338910367
|
1032100
|
2013-02-10
|
F/T SEAFREEZE ALASKA OSI DOCK, DUTCH HARBOR, AK, 99692
|
|
Inspection Type |
Planned |
Scope |
Complete |
Safety/Health |
Safety |
Close Conference |
2013-02-10 |
Emphasis |
N: AMPUTATE, L: FISH, P: FISH |
Case Closed |
2013-05-15 |
Related Activity
Type |
Inspection |
Activity Nr |
891043 |
Health |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
5A0001 |
Issuance Date |
2013-03-11 |
Abatement Due Date |
2013-04-04 |
Current Penalty |
4200.0 |
Initial Penalty |
7000.0 |
Final Order |
2013-05-09 |
Nr Instances |
5 |
Nr Exposed |
3 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees. Seafreeze Alaska: On or about 10 February 2013 and times prior thereto: (a) Power Panel P421 located in prop motor room and Power Panel P4303 located in the machinist room was missing blanks exposing employees to a 440 volt shock and electrocution hazard. (b) Delta Belt Sander in the carpenter/wood shop had exposed wires exposing employees to a 110 volt electrical shock and burn hazard. (c) Unguarded light bulb/fixture in the compressor room exposing employees to a 110 volt electrical shock and burn hazard. (d) Partially uncovered electrical outlet cover exposing employees to a 110 volt electrical shock and burn hazard |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100212 A05 |
Issuance Date |
2013-03-11 |
Abatement Due Date |
2013-04-11 |
Current Penalty |
1530.0 |
Initial Penalty |
2550.0 |
Final Order |
2013-05-09 |
Nr Instances |
3 |
Nr Exposed |
3 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.212(a)(5): Fan blade guard(s) were not provided where the periphery of the blades was less than seven feet from the floor or working level. (a) Fiber Room: On or about 10 February 2013 and times prior thereto the Qmark fan did not have guards installed. The fan was approximately five feet from the floor. This condition exposed employees to a caught in hazard. (b) Generator Room: On or about 10 February 2013 and times prior thereto the Taskmaster fan did not have guards installed. The fan was approximately six feet, four inches from the floor. This condition exposed employees to a caught in hazard. (c) Prop Motor Room: On or about 10 February 2013 and times prior thereto the QMark fan did not have guards installed. The fan was approximately six feet from the floor. This condition exposed employees to a caught in hazard. |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19100253 B04 I |
Issuance Date |
2013-03-11 |
Abatement Due Date |
2013-04-11 |
Current Penalty |
1530.0 |
Initial Penalty |
2550.0 |
Final Order |
2013-05-09 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.253(b)(4)(i): Oxygen cylinders were stored near highly combustible material, especially oil and grease; or near reserve stocks of carbide and acetylene or other fuel-gas cylinders, or near other substance likely to cause or accelerate fire. Welding Shop Area: On or about 10 February 2013 and times prior thereto, an unused cylinder of acetylene and a cylinder of oxygen were stored beside cylinders of acetylene and a bottle of oxygen. This condition exposed employees to a fire hazard. |
|
|
331921684
|
1032100
|
2012-02-15
|
F/T LEGACY OSI DOCK, DUTCH HARBOR, AK, 99692
|
|
Inspection Type |
Planned |
Scope |
Complete |
Safety/Health |
Safety |
Close Conference |
2012-02-15 |
Emphasis |
L: FISH, N: AMPUTATE |
Case Closed |
2012-04-11 |
Related Activity
Type |
Inspection |
Activity Nr |
192150 |
Health |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
5A0001 |
Issuance Date |
2012-03-09 |
Abatement Due Date |
2012-04-06 |
Current Penalty |
2550.0 |
Initial Penalty |
4250.0 |
Final Order |
2012-04-11 |
Nr Instances |
2 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to electrical hazards in the engine room: (a) F/T Legacy (Engine Room): On or about February 15, 2012, and times prior thereto employees were exposed to electrical shock hazards due to unguarded openings exposing energized busbars on Panel P-401. (b) F/T Legacy (Engine Room): On or about February 15, 2012, and times prior thereto employees were exposed to electrical shock hazards due to unguarded openings exposing energized busbars on Panel 201. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100215 B09 |
Issuance Date |
2012-03-09 |
Abatement Due Date |
2012-04-06 |
Current Penalty |
1428.0 |
Initial Penalty |
2380.0 |
Final Order |
2012-04-11 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.215(b)(9): Exposure adjustment. Safety guards of the types described in Subparagraphs (3) and (4) of this paragraph, where the operator stands in front of the opening, shall be constructed so that the peripheral protecting member can be adjusted to the constantly decreasing diameter of the wheel. The maximum angular exposure above the horizontal plane of the wheel spindle as specified in paragraphs(b)(3) and (4) of this section shall never be exceeded, and the distance between the wheel periphery and the adjustable tongue or the end of the peripheral member at the top shall never exceed one-fourth inch. F/T Legacy (Engineering room): On or about 2/15/2012, and times prior thereto, the tongue guard on the DeWalt bench grinder was not used leaving a 1/2 inch gap; exposing employees to the hazard of being struck by material in the event of wheel failure. |
|
|
331921502
|
1032100
|
2012-02-15
|
F/T LEGACY, DUTCH HARBOR, AK, 99692
|
|
Inspection Type |
Planned |
Scope |
Complete |
Safety/Health |
Health |
Close Conference |
2012-02-15 |
Emphasis |
L: FISH, N: AMPUTATE |
Case Closed |
2012-04-11 |
Related Activity
Type |
Inspection |
Activity Nr |
192168 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19180035 |
Issuance Date |
2012-03-09 |
Abatement Due Date |
2012-04-06 |
Current Penalty |
2940.0 |
Initial Penalty |
4900.0 |
Final Order |
2012-04-11 |
Nr Exposed |
3 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1918.35: Employees were working around open weather deck hatches which were not protected by coamings to a height of 24 inches (0.61 m), or by taut lines or barricades at a height of 36 to 42 inches (0.91 m to 1.07 m) above the deck: Weather Deck, Off Load Hatch: On or about February 15, 2012 and at times prior thereto, the the top chain rail adjacent to the work area was at a slack height of 31 inches and a high deflected height of 54 inches. The mid chain rail was at a slack height of 15 inches and a high deflected height of 28 inches. The lack of maintaining a consistent chain rail height to offer fall protection exposed employees to fall hazards of up to 17 feet. |
|
|
331920983
|
1032100
|
2012-02-14
|
F/T SEAFREEZE ALASKA OSI DOCK, DUTCH HARBOR, AK, 99692
|
|
Inspection Type |
Planned |
Scope |
Records |
Safety/Health |
Safety |
Close Conference |
2012-02-14 |
Emphasis |
L: FISH, N: AMPUTATE |
Case Closed |
2012-03-23 |
|
307504118
|
1032100
|
2009-02-01
|
F/T LEGACY, DUTCH HARBOR, AK, 99692
|
|
Inspection Type |
Planned |
Scope |
Complete |
Safety/Health |
Health |
Close Conference |
2009-02-01 |
Emphasis |
L: FISH, S: NOISE |
Case Closed |
2009-04-14 |
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100095 D01 |
Issuance Date |
2009-02-23 |
Abatement Due Date |
2009-03-26 |
Current Penalty |
585.0 |
Initial Penalty |
975.0 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
01 |
|
|
307504332
|
1032100
|
2009-02-01
|
F/T LEGACY, DUTCH HARBOR, AK, 99692
|
|
Inspection Type |
Planned |
Scope |
Complete |
Safety/Health |
Safety |
Close Conference |
2009-02-01 |
Emphasis |
L: FISH |
Case Closed |
2009-02-23 |
|
307504092
|
1032100
|
2009-01-30
|
F/T ALLIANCE, DUTCH HARBOR, AK, 99692
|
|
Inspection Type |
Planned |
Scope |
Complete |
Safety/Health |
Health |
Close Conference |
2009-01-30 |
Emphasis |
L: FISH, S: NOISE |
Case Closed |
2009-04-14 |
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100133 A01 |
Issuance Date |
2009-02-23 |
Abatement Due Date |
2009-03-26 |
Current Penalty |
2400.0 |
Initial Penalty |
4000.0 |
Nr Instances |
1 |
Nr Exposed |
8 |
Gravity |
10 |
|
|
307504324
|
1032100
|
2009-01-30
|
F/T ALLIANCE, DUTCH HARBOR, AK, 99692
|
|
Inspection Type |
Planned |
Scope |
Complete |
Safety/Health |
Safety |
Close Conference |
2009-01-30 |
Emphasis |
S: FALL FROM HEIGHT, L: FISH |
Case Closed |
2009-04-14 |
Violation Items
Citation ID |
01001 |
Citaton Type |
Other |
Standard Cited |
19101200 G01 |
Issuance Date |
2009-02-23 |
Abatement Due Date |
2009-03-26 |
Nr Instances |
1 |
Nr Exposed |
7 |
Gravity |
01 |
|
|
307504068
|
1032100
|
2009-01-29
|
F/T SEAFREEZE ALASKA, DUTCH HARBOR, AK, 99692
|
|
Inspection Type |
Planned |
Scope |
Complete |
Safety/Health |
Health |
Close Conference |
2009-01-29 |
Emphasis |
L: FISH, S: FALL FROM HEIGHT, S: NOISE, S: STRUCK-BY |
Case Closed |
2009-04-14 |
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100095 D01 |
Issuance Date |
2009-02-24 |
Abatement Due Date |
2009-03-27 |
Current Penalty |
585.0 |
Initial Penalty |
975.0 |
Nr Instances |
1 |
Nr Exposed |
4 |
Gravity |
01 |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100134 H02 I |
Issuance Date |
2009-02-24 |
Abatement Due Date |
2009-03-27 |
Current Penalty |
585.0 |
Initial Penalty |
975.0 |
Nr Instances |
2 |
Nr Exposed |
2 |
Gravity |
01 |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19100242 B |
Issuance Date |
2009-02-24 |
Abatement Due Date |
2009-03-27 |
Current Penalty |
405.0 |
Initial Penalty |
675.0 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
01 |
|
|
307504340
|
1032100
|
2009-01-29
|
F/T SEAFREEZE ALASKA, DUTCH HARBOR, AK, 99692
|
|
Inspection Type |
Planned |
Scope |
Complete |
Safety/Health |
Safety |
Close Conference |
2009-01-29 |
Emphasis |
L: FISH, S: STRUCK-BY, S: FALL FROM HEIGHT |
Case Closed |
2009-04-14 |
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19180035 |
Issuance Date |
2009-02-24 |
Abatement Due Date |
2009-03-13 |
Current Penalty |
2400.0 |
Initial Penalty |
4000.0 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
10 |
|
|
307502690
|
1032100
|
2008-01-29
|
F/T OCEAN ALASKA, DUTCH HARBOR, AK, 99692
|
|
Inspection Type |
Planned |
Scope |
Complete |
Safety/Health |
Safety |
Close Conference |
2008-01-29 |
Emphasis |
S: POWERED IND VEHICLE, S: STRUCK-BY, L: FISH, S: FALL FROM HEIGHT |
Case Closed |
2008-07-28 |
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100023 A09 |
Issuance Date |
2008-02-25 |
Abatement Due Date |
2008-03-27 |
Current Penalty |
1200.0 |
Initial Penalty |
1200.0 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
01 |
|
Citation ID |
01002A |
Citaton Type |
Serious |
Standard Cited |
19100024 F |
Issuance Date |
2008-02-25 |
Abatement Due Date |
2008-03-27 |
Current Penalty |
1600.0 |
Initial Penalty |
1600.0 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
02 |
|
Citation ID |
01002B |
Citaton Type |
Serious |
Standard Cited |
19100024 H |
Issuance Date |
2008-02-25 |
Abatement Due Date |
2008-03-27 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
02 |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19150134 G |
Issuance Date |
2008-02-25 |
Abatement Due Date |
2008-03-27 |
Current Penalty |
2000.0 |
Initial Penalty |
2000.0 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
03 |
|
Citation ID |
01004 |
Citaton Type |
Serious |
Standard Cited |
19180091 B |
Issuance Date |
2008-02-25 |
Abatement Due Date |
2008-03-27 |
Current Penalty |
1600.0 |
Initial Penalty |
1600.0 |
Nr Instances |
2 |
Nr Exposed |
1 |
Gravity |
02 |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19030019 C01 |
Issuance Date |
2008-05-23 |
Abatement Due Date |
2008-06-25 |
Current Penalty |
1000.0 |
Initial Penalty |
1000.0 |
Nr Instances |
5 |
Nr Exposed |
1 |
Gravity |
00 |
|
|
307502575
|
1032100
|
2008-01-29
|
F/T OCEAN ALASKA, DUTCH HARBOR, AK, 99692
|
|
Inspection Type |
Planned |
Scope |
Complete |
Safety/Health |
Health |
Close Conference |
2008-01-29 |
Emphasis |
L: FISH, S: NOISE, S: ELECTRICAL |
Case Closed |
2008-07-08 |
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
5A0001 |
Issuance Date |
2008-02-25 |
Abatement Due Date |
2008-03-27 |
Current Penalty |
4000.0 |
Initial Penalty |
4000.0 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
10 |
Hazard |
ELECTRIC |
|
Citation ID |
02001 |
Citaton Type |
Repeat |
Standard Cited |
19100253 B04 I |
Issuance Date |
2008-02-25 |
Abatement Due Date |
2008-03-27 |
Current Penalty |
2400.0 |
Initial Penalty |
2400.0 |
Nr Instances |
1 |
Nr Exposed |
14 |
Gravity |
01 |
|
Citation ID |
03001 |
Citaton Type |
Other |
Standard Cited |
19040029 B01 |
Issuance Date |
2008-02-25 |
Abatement Due Date |
2008-03-27 |
Current Penalty |
1000.0 |
Initial Penalty |
1000.0 |
Nr Instances |
5 |
Nr Exposed |
19 |
Gravity |
00 |
|
Citation ID |
03002 |
Citaton Type |
Other |
Standard Cited |
19101200 F05 I |
Issuance Date |
2008-02-25 |
Abatement Due Date |
2008-03-27 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
01 |
|
Citation ID |
04001 |
Citaton Type |
Other |
Standard Cited |
19030019 C01 |
Issuance Date |
2008-05-23 |
Abatement Due Date |
2008-06-25 |
Current Penalty |
1000.0 |
Initial Penalty |
1000.0 |
Nr Instances |
4 |
Nr Exposed |
5 |
Gravity |
00 |
|
|
307501106
|
1032100
|
2007-01-30
|
F/T SEAFREEZE ALASKA, DUTCH HARBOR, AK, 99692
|
|
Inspection Type |
Planned |
Scope |
Complete |
Safety/Health |
Health |
Close Conference |
2007-01-30 |
Emphasis |
L: FISH |
Case Closed |
2007-05-21 |
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100023 A03 |
Issuance Date |
2007-03-06 |
Abatement Due Date |
2007-04-06 |
Current Penalty |
560.0 |
Initial Penalty |
700.0 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
02 |
|
Citation ID |
01002A |
Citaton Type |
Serious |
Standard Cited |
19100253 B02 IV |
Issuance Date |
2007-03-06 |
Abatement Due Date |
2007-04-06 |
Current Penalty |
420.0 |
Initial Penalty |
525.0 |
Nr Instances |
6 |
Nr Exposed |
75 |
Gravity |
01 |
|
Citation ID |
01002B |
Citaton Type |
Serious |
Standard Cited |
19100253 B04 I |
Issuance Date |
2007-03-06 |
Abatement Due Date |
2007-03-09 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
01 |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19040029 A |
Issuance Date |
2007-03-06 |
Abatement Due Date |
2007-04-06 |
Nr Instances |
3 |
Nr Exposed |
75 |
Gravity |
00 |
|
Citation ID |
02002 |
Citaton Type |
Other |
Standard Cited |
19101030 C01 I |
Issuance Date |
2007-03-06 |
Abatement Due Date |
2007-04-06 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
01 |
|
Citation ID |
02003 |
Citaton Type |
Other |
Standard Cited |
19101200 E01 |
Issuance Date |
2007-03-06 |
Abatement Due Date |
2007-04-06 |
Nr Instances |
1 |
Nr Exposed |
75 |
Gravity |
01 |
|
|
307501262
|
1032100
|
2007-01-30
|
F/T SEAFREEZE ALASKA, DUTCH HARBOR, AK, 99692
|
|
Inspection Type |
Planned |
Scope |
Complete |
Safety/Health |
Safety |
Close Conference |
2007-01-30 |
Emphasis |
N: AMPUTATE, L: FISH, S: ELECTRICAL |
Case Closed |
2007-05-21 |
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100137 B02 VIII |
Issuance Date |
2007-03-06 |
Abatement Due Date |
2007-04-06 |
Current Penalty |
420.0 |
Initial Penalty |
525.0 |
Nr Instances |
2 |
Nr Exposed |
2 |
Gravity |
01 |
|
Citation ID |
01002A |
Citaton Type |
Serious |
Standard Cited |
19100215 A04 |
Issuance Date |
2007-03-06 |
Abatement Due Date |
2007-04-06 |
Current Penalty |
560.0 |
Initial Penalty |
700.0 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
02 |
|
Citation ID |
01002B |
Citaton Type |
Serious |
Standard Cited |
19100215 B09 |
Issuance Date |
2007-03-06 |
Abatement Due Date |
2007-04-06 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
02 |
|
Citation ID |
01002C |
Citaton Type |
Serious |
Standard Cited |
19100215 D01 |
Issuance Date |
2007-03-06 |
Abatement Due Date |
2007-04-06 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
02 |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19100022 A01 |
Issuance Date |
2007-03-06 |
Abatement Due Date |
2007-04-06 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
01 |
|
Citation ID |
02002 |
Citaton Type |
Other |
Standard Cited |
19100151 C |
Issuance Date |
2007-03-06 |
Abatement Due Date |
2007-04-06 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
01 |
|
|