342047149
|
1032100
|
2017-01-18
|
819 CASE AVENUE, WRANGELL, AK, 99929
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Health
|
Close Conference |
2017-01-18
|
Emphasis |
L: SHIP, P: SHIP
|
Case Closed |
2018-02-28
|
Related Activity
Type |
Inspection |
Activity Nr |
1204719 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100242 B |
Issuance Date |
2017-02-21 |
Abatement Due Date |
2017-03-21 |
Current Penalty |
1500.0 |
Initial Penalty |
2716.0 |
Final Order |
2017-03-20 |
Nr Instances |
3 |
Nr Exposed |
3 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.: Main Shop: On or about January 18, 2017 and at times prior thereto, compressed air for cleaning measured 90 p.s.i.g. at the nozzle. This condition exposed employees to air embolism hazards in the event of skin contact. 29 CFR 1910 General Industry Standard applicable to shipyard employment. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19150056 E |
Issuance Date |
2017-02-21 |
Abatement Due Date |
2017-03-21 |
Current Penalty |
1500.0 |
Initial Penalty |
2716.0 |
Final Order |
2017-03-20 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1915.56(e): Arc welding and cutting operations were not shielded by noncombustible or flameproof screens to protect employees in the vicinity from the direct rays of the arc: (a) Main Shop: On or about January 18, 2017 and at times prior thereto, flameproof screens were not provided where practicable during MIG welding operations. This condition exposed employees to eye injuries. |
|
Citation ID |
01003A |
Citaton Type |
Serious |
Standard Cited |
19150502 A |
Issuance Date |
2017-02-21 |
Abatement Due Date |
2017-03-21 |
Current Penalty |
600.0 |
Initial Penalty |
1630.0 |
Final Order |
2017-03-20 |
Nr Instances |
1 |
Nr Exposed |
6 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1915.502(a): A written fire safety plan was not been developed and implemented by the employer that covered all of the actions necessary to ensure the employees safety in the event of a fire: Main Shop: On or about January 18, 2017 and at times prior thereto, where welding and other hot work operations were conducted, the employer had not developed a written fire safety plan. This condition exposed employees to fire and smoke-inhalation hazards. |
|
Citation ID |
01003B |
Citaton Type |
Serious |
Standard Cited |
19150505 F02 I |
Issuance Date |
2017-02-21 |
Abatement Due Date |
2017-03-21 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2017-03-20 |
Nr Instances |
3 |
Nr Exposed |
6 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1915.505(f)(2)(i): The fire response equipment was not kept in a state of readiness: Main Shop: Fire extinguishers used for fire suppression were not maintained in a state of readiness. Fire extinguishers were not readily accessible and had not been regularly inspected. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19101200 E01 |
Issuance Date |
2017-02-21 |
Abatement Due Date |
2017-03-21 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2017-03-20 |
Nr Instances |
1 |
Nr Exposed |
3 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: Main Shop: On or about January 18, 2017 and at times prior thereto, the employer had not developed a written Hazard Communication program where chemicals such as Super Clean and Sunnyside Lacquer Thinner were used. This condition limited employee information to hazardous chemicals within their workplace and exposed employees to inhalation, skin contact, eye contact, fire and smoke-inhalation injuries. 29 CFR 1910 General Industry standard applicable to shipyard employment. |
|
Citation ID |
02002 |
Citaton Type |
Other |
Standard Cited |
19150152 B04 |
Issuance Date |
2017-02-21 |
Abatement Due Date |
2017-03-21 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2017-03-20 |
Nr Instances |
1 |
Nr Exposed |
6 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1915.152(b)(4): The employer failed to document an occupational hazard assessment which should have included: Occupations involved in the survey, the date in which the survey took place and the name of the person who performed the hazard assessment: Main Shop: On or about January 18, 2017 and at times prior thereto, the employer had not documented that a hazard assessment had not been conducted. This condition limited employee knowledge of personal protective equipment required when performing their work. |
|
|
342047198
|
1032100
|
2017-01-18
|
819 CASE AVENUE, WRANGELL, AK, 99929
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2017-01-18
|
Emphasis |
L: SHIP, P: SHIP
|
Case Closed |
2018-02-28
|
Related Activity
Type |
Inspection |
Activity Nr |
1204714 |
Health |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100212 B |
Issuance Date |
2017-02-21 |
Abatement Due Date |
2017-03-21 |
Current Penalty |
900.0 |
Initial Penalty |
1630.0 |
Final Order |
2017-03-20 |
Nr Instances |
2 |
Nr Exposed |
6 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.212(b): Machine(s) designed for fixed location(s) were not securely anchored to prevent walking or moving. (a) Shop Area: On or about 18 January 2017 and times prior thereto, the Delta Shop Master Drill Press, number 021897W4041, was not secured to a fixed location. This condition exposed employees to a struck by hazard. (b) Shop Area: On or about 18 January 2017 and times prior thereto, the Foremost Machinery Drill Press, number MADP081BMA, was not secured to a fixed location. This condition exposed employees to a struck by hazard. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100303 G01 I B |
Issuance Date |
2017-02-21 |
Abatement Due Date |
2017-03-21 |
Current Penalty |
800.0 |
Initial Penalty |
1630.0 |
Final Order |
2017-03-20 |
Nr Instances |
1 |
Nr Exposed |
6 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.303(g)(1)(i)(B): For electric equipment operating at 600 volts, nominal, or less to ground, and likely to require examination, adjustment, servicing, or maintenance while energized, the width of the working space in front of electrical equipment was less than the width of the equipment or 762 mm (30 inches), whichever was greater. North Corner: On or about 18 January 2017 and times prior thereto, the 120/208 volt electrical panels were blocked. This condition exposed employees to an electrical shock and burn hazard. |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19100305 G02 III |
Issuance Date |
2017-02-21 |
Abatement Due Date |
2017-03-21 |
Current Penalty |
800.0 |
Initial Penalty |
1630.0 |
Final Order |
2017-03-20 |
Nr Instances |
1 |
Nr Exposed |
6 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws: Main floor: On or about 18 January 2017 and times prior thereto, the 3-Ton Jet Hoist electrical connector exhibited strain relief. This condition exposed employees to an electrical shock and burn hazard. |
|
|