Search icon

SUPERIOR MARINE SERVICES LLC

Contents

Company Details

Name: SUPERIOR MARINE SERVICES LLC
Jurisdiction: Alaska
Legal type: Limited Liability Company
Status: Good Standing
Date of registration: 04 Oct 2010 (14 years ago)
Entity Number: 130939
ZIP code: 99929
County: Wrangell
Place of Formation: ALASKA
Address: 523 FRONT ST LOT#1 WRANGELL AK 99929, 523 FRONT ST WRANGELL AK 99929, WRANGELL, AK 99929
Mailing Address: P.O. BOX 2296, WRANGELL, AK 99929

Activity

Line of Business

31-33 Manufacturing

NAICS

336611 SHIP BUILDING AND REPAIRING

Officers

Name Role
Donald T Sorric Manager
Donald T Sorric Member
DONALD SORRIC Registered Agent

Unique Entity ID

Unique Entity ID Expiration Date Physical Address
G4K6D6G58VJ3 2023-04-27 523 FRONT ST, WRANGELL, AK, 99929, USA
Mailing Address PO BOX 2296, WRANGELL, AK, 99929, 2296, USA

Business Information

Division Name SUPERIOR MARINE SERVICES LLC
Division Number SUPERIOR M
Congressional District 00
State/Country of Incorporation AK, USA
Activation Date 2022-03-30
Initial Registration Date 2021-03-25
Entity Start Date 2007-05-01
Fiscal Year End Close Date Dec 31

Service Classifications

NAICS Codes 336611

Points of Contacts

Electronic Business
Title PRIMARY POC
Name DONALD T SORRIC
Role OWNER
Address PO BOX 2296, 523 FRONT ST, WRANGELL, AK, 99929, 2296, USA
Government Business
Title PRIMARY POC
Name DONALD T SORRIC
Role OWNER
Address PO BOX 2296, 523 FRONT ST, WRANGELL, AK, 99929, 2296, USA
Past Performance -

Business Licenses

License Number Type Status Issue Date Date of renewal Expiration date Description
948635 Business License Active 2010-10-05 2023-10-16 2025-12-31 LOB: 31-33 - Manufacturing, NAICS: 336611 - SHIP BUILDING AND REPAIRING

Awards

Contract Type Award or IDV Flag PIID Start Date Current End Date Potential End Date
DEFINITIVE CONTRACT AWARD 1240BF24C0003 2024-08-20 2024-10-31 2024-10-31
Unique Award Key CONT_AWD_1240BF24C0003_12C2_-NONE-_-NONE-
Awarding Agency Department of Agriculture
Link View Page

Award Amounts

Obligated Amount 21000.00
Current Award Amount 21000.00
Potential Award Amount 21000.00

Description

Title LE&I REMOVAL AND REAPPLICATION OF ANTIFOULING ZINC-BASED BOTTOM PAINT
NAICS Code 238320: PAINTING AND WALL COVERING CONTRACTORS
Product and Service Codes J019: MAINT/REPAIR/REBUILD OF EQUIPMENT- SHIPS, SMALL CRAFT, PONTOONS, AND FLOATING DOCKS

Recipient Details

Recipient SUPERIOR MARINE SERVICES LLC
UEI G4K6D6G58VJ3
Recipient Address UNITED STATES, 523 FRONT ST LOT 1, WRANGELL, WRANGELL, ALASKA, 99929

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
343198057 1032100 2018-05-30 523 FRONT STREET, WRANGELL, AK, 99929
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2018-05-30
Emphasis L: SHIP, P: SHIP
Case Closed 2019-01-14

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19100029 B01
Issuance Date 2018-06-11
Abatement Due Date 2018-07-10
Current Penalty 1178.0
Initial Penalty 2356.0
Final Order 2018-06-22
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.29(b)(1): The top edge height of top rails, or equivalent guardrail system members, were not 42 inches, plus or minus 3 inches, above the walking-working surface: Building 1, Upper Storage Landing: On or about May 30, 2018 and at times prior thereto, the steel top rail was measured at 33 inches above the walking and working surface. This condition exposed employees to a fall hazard of 11 feet 6 inches to the concrete surface below.
Citation ID 01002A
Citaton Type Serious
Standard Cited 19100134 I01 II
Issuance Date 2018-06-11
Abatement Due Date 2018-07-10
Current Penalty 1413.5
Initial Penalty 2827.0
Final Order 2018-06-22
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.134(i)(1)(ii): Breathing air did not meet requirements for Grade D breathing air as described in the ANSI/Compressed Gas Association Commodity Specification G-7.1-1989: Buildings 1 and 2: On or about May 30, 2018 and at times prior thereto, the employer could not confirm that breathing air for supplied-air helmets could meet Grade D requirements. This condition exposed employees to inhalation hazards in the event of inadequate supplied breathing air.
Citation ID 01002B
Citaton Type Serious
Standard Cited 19100134 I05 IV
Issuance Date 2018-06-11
Abatement Due Date 2018-07-10
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2018-06-22
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.134(i)(5)(iv): The tag containing the most recent change to the sorbent beds was not kept or maintained at the compressor: Buildings 1 and 2: On or about May 30, 2018 and at times prior thereto, a tag indicating the most recent change date of the filter sorbents was not maintained at the compressor(s). This condition exposed employees to inhalation hazards in the event of inadequate supplied breathing air.
Citation ID 01002C
Citaton Type Serious
Standard Cited 19100134 I07
Issuance Date 2018-06-11
Abatement Due Date 2018-07-10
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2018-06-22
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.134(i)(7): Oil lubricated compressor(s) used to supply breathing air did not have a high-temperature or carbon monoxide alarm(s) or both: Buildings 1 and 2: On or about May 30, 2018 and at times prior thereto, The oil-lubricated, diesel-powered Sullair 375, M/N 375DPO CAT, S/N 004-133222 compressor did not have a high-temperature or carbon monoxide alarms(s) or both. This condition exposed employees to inhalation hazards in the event of inadequate supplied breathing air.
340205376 1032100 2015-01-22 523 FRONT STREET, WRANGELL, AK, 99929
Inspection Type Complaint
Scope Complete
Safety/Health Health
Close Conference 2015-01-22
Emphasis L: SHIP, P: SHIP
Case Closed 2016-05-18

Related Activity

Type Complaint
Activity Nr 933228
Safety Yes
Health Yes
Type Inspection
Activity Nr 1020545
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 5A0001
Issuance Date 2015-02-24
Abatement Due Date 2015-03-24
Current Penalty 550.8
Initial Penalty 918.0
Final Order 2015-03-24
Nr Instances 3
Nr Exposed 5
Gravity 1
FTA Current Penalty 0.0
Citation text line OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees: (a) Dry Space: On or about January 22, 2015 and at times prior thereto, whip protection was not provided for the 2 inch compressed air hose coming from the Sullair 375 air compressor. This condition exposed employees to struck-by hazards. (b) Tool Container: On or about January 22, 2015 and at times prior thereto, whip protection was not provided for the 1 inch compressed air inlet hose coming for the Zeks NC Series Air Dryer. This condition exposed employees to struck-by hazards. (c) Tool Container: On or about January 22, 2015 and at times prior thereto, whip protection was not provided for the breathing air connection on the CPF Air Filter. This condition exposed employees to struck-by hazards. Among other feasible methods of correcting the hazard, the inclusion of keeper clips to prevent disengagement of the fittings would reduce the struck-by hazard.
Citation ID 01002A
Citaton Type Serious
Standard Cited 19100134 C02 I
Issuance Date 2015-02-24
Abatement Due Date 2015-05-24
Current Penalty 550.8
Initial Penalty 918.0
Final Order 2015-03-24
Nr Instances 1
Nr Exposed 5
Related Event Code (REC) Complaint
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.134(c)(2)(i): Respirator users were not provided with the information contained in Appendix D to 29 CFR 1910.134 when the employer determined that any voluntary respirator use was permissible: Yard: On or about January 22, 2015 and at times prior thereto, where tight-fitting, half-mask, negative pressure respirators were provided for voluntary use, information included in Appendix D of the standard was not provided to employees. This condition limited employee pertinent information to employees regarding the limitations of voluntary respirator use.
Citation ID 01002B
Citaton Type Serious
Standard Cited 19100134 C02 II
Issuance Date 2015-02-24
Abatement Due Date 2015-05-24
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2015-03-24
Nr Instances 1
Nr Exposed 5
Related Event Code (REC) Complaint
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.134(c)(2)(ii): The employer did not establish and implement those elements of a written program necessary to ensure that any employee using a respirator voluntarily was medically able to use that respirator, and that the respirator was cleaned, stored, and maintained so that its use does not present a health hazard to the user: Yard: On or about January 22, 2015 and at times prior thereto, where tight-fitting, half-mask, negative pressure respirators were provided for voluntary use, the employer had not developed and implemented elements of a written respiratory protection program for medical surveillance and to ensure respirators were cleaned, stored and maintained properly. This condition limited employee information on the proper care and use of respiratory protection.
Citation ID 01003A
Citaton Type Serious
Standard Cited 19150502 A
Issuance Date 2015-02-24
Abatement Due Date 2015-05-24
Current Penalty 1101.6
Initial Penalty 1836.0
Final Order 2015-03-24
Nr Instances 1
Nr Exposed 5
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1915.502(a): A written fire safety plan was not been developed and implemented by the employer that covered all of the actions necessary to ensure the employees safety in the event of a fire: Yard: On or about January 22, 2015 and at times prior thereto, where hot work and other welding processes were used, a written fire safety plan had not been developed or implemented. This condition exposed employee to fire and smoke inhalation injuries in the event of fire.
Citation ID 01003B
Citaton Type Serious
Standard Cited 19150507 B01
Issuance Date 2015-02-24
Abatement Due Date 2015-05-24
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2015-03-24
Nr Instances 2
Nr Exposed 5
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1915.507(b)(1): The portable fire extinguishers and hose systems were not selected, installed, inspected, maintained, and tested by the employer according to NFPA 10-2002 Standard for Portable Fire Extinguishers: Dry Space: On or about January 22, 2015 and at times prior thereto, where hot work and other welding processes were used, portable fire extinguishers were not immediately available for use nor were they regularly inspected to ensure they were ready for use. This condition exposed employees to fire and smoke inhalation hazards.
Citation ID 01003C
Citaton Type Serious
Standard Cited 19100253 B04 III
Issuance Date 2015-02-24
Abatement Due Date 2015-05-24
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2015-03-24
Nr Instances 1
Nr Exposed 5
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet: Outside Storage: On or about January 22, 2015 and at times prior thereto, 16 oxygen cylinders were stored adjacent to four (4) fuel gas (acetylene) cylinders and five (5) fuel containers. This condition exposed employees to fire and smoke-inhalation injuries.
Citation ID 02001
Citaton Type Other
Standard Cited 19101200 E01
Issuance Date 2015-02-24
Abatement Due Date 2015-05-24
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2015-03-24
Nr Instances 1
Nr Exposed 5
Related Event Code (REC) Complaint
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: Yard Facility: On or about January 22, 2015 and at times prior thereto, where various paints, solvents, compressed gases, and petroleum products were used in regards to ship repair work, the employer had not developed a written hazard communication program. This condition limited employee information to hazardous chemicals in their work area(s)
Citation ID 02002
Citaton Type Other
Standard Cited 19150152 B04
Issuance Date 2015-02-24
Abatement Due Date 2015-03-24
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2015-03-24
Nr Instances 1
Nr Exposed 5
Related Event Code (REC) Complaint
FTA Current Penalty 0.0
Citation text line 29 CFR 1915.152(b)(4): The employer failed to document an occupational hazard assessment which should have included: Occupations involved in the survey, the date in which the survey took place and the name of the person who performed the hazard assessment: Yard: On or about January 22, 2015 and at times prior thereto, where personal protective equipment (PPE) was provided and used in the workplace, the employer had not performed a workplace assessment to ensure proper PPE selection. This condition exposed employees to eye, hand, noise, struck-by, and inhalation injuries from the improper selection and use of PPE.
340205459 1032100 2015-01-22 523 FRONT STREET, WRANGELL, AK, 99929
Inspection Type Complaint
Scope Complete
Safety/Health Safety
Close Conference 2015-01-22
Emphasis L: SHIP, P: SHIP
Case Closed 2016-05-18

Related Activity

Type Inspection
Activity Nr 1020537
Health Yes
Type Complaint
Activity Nr 933228
Safety Yes
Health Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19100303 G02 II
Issuance Date 2015-02-24
Abatement Due Date 2015-03-24
Current Penalty 550.8
Initial Penalty 918.0
Final Order 2015-03-27
Nr Instances 2
Nr Exposed 3
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.303(g)(2)(ii): In locations where electric equipment was likely to be exposed to physical damage, enclosures or guards were not so arranged and of such strength as to prevent such damage: Tool Container: On or about 22 January 2015 and times prior thereto, two mercury vapor lights measuring approximately 81 inches from the floor were not protected. This condition exposed employees to an electrical shock and burn hazard.
Citation ID 01002
Citaton Type Serious
Standard Cited 19100304 G05
Issuance Date 2015-02-24
Abatement Due Date 2015-03-24
Current Penalty 550.8
Initial Penalty 918.0
Final Order 2015-03-27
Nr Instances 1
Nr Exposed 3
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective: Tool Container: On or about 22 January 2015 and times prior thereto, a 100 foot bluish green extension cord missing a ground pin. this condition exposed employees to an electrical shock and burn hazard.
Citation ID 01003A
Citaton Type Serious
Standard Cited 19100305 B01 II
Issuance Date 2015-02-24
Abatement Due Date 2015-03-24
Current Penalty 550.8
Initial Penalty 918.0
Final Order 2015-03-27
Nr Instances 2
Nr Exposed 3
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed: (a) Tool Container: On or about 22 January 2015 and times prior thereto, 240v electrical panel missing a 4"x 5" cover plate. This condition exposed employees to an electrical shock hazard. (b) Dry Space Area/Painting Area: On or about 22 January 2015 and times prior thereto, 120v electrical cover missing a cover plate. This condition exposed employees to an electrical shock hazard.
Citation ID 01003B
Citaton Type Serious
Standard Cited 19100305 G02 III
Issuance Date 2015-02-24
Abatement Due Date 2015-03-24
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2015-03-27
Nr Instances 2
Nr Exposed 3
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws: (a) Outside, ground area by F/V Marauder: On or about 22 January 2015 and times prior thereto, a 100 foot bluish extension cord had evidence of strain relief on the electrical connector. This condition exposed employees to an electrical shock and burn hazard. (b) Tool container: On or about 22 January 2015 and times prior thereto, a mercury vapor light assembly had evidence of strain relief on the electrical connector. This condition exposed employees to an electrical shock and burn hazard
Citation ID 01004A
Citaton Type Serious
Standard Cited 19150072 A01
Issuance Date 2015-02-24
Abatement Due Date 2015-03-24
Current Penalty 734.4
Initial Penalty 1224.0
Final Order 2015-03-27
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1915.72(a)(1): ladders with broken or missing Rungs or steps, broken or split side rails, or other faulty or defective construction were used. F/V Josie J: On or about 22 January 2015 and times prior thereto, employees using a 15 foot aluminum ladder to access the vessel with damaged footings. This condition exposed employees to a fall hazard.
Citation ID 01004B
Citaton Type Serious
Standard Cited 19150072 A03
Issuance Date 2015-02-24
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2015-03-27
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1915.72(a)(3): The side rails of ladders used for access to any level extended less than 36 inches above that level. F/V Josie J: On or about 22 January 2015 and times prior thereto, employees using a 15 foot aluminum ladder to access the vessel without ladder extended 36 inches of the vessel railing. This condition exposed employees to a 12 foot fall hazard.
Citation ID 01005
Citaton Type Serious
Standard Cited 19150073 D
Issuance Date 2015-02-24
Abatement Due Date 2015-03-24
Current Penalty 734.4
Initial Penalty 1224.0
Final Order 2015-03-27
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1915.73(d): When employees were exposed to unguarded edges of decks, platforms, flats, or similar flat surfaces, more than 5 feet above a solid surface, the edges were not guarded by adequate guardrails meeting the requirements of 29 CFR 1915.71(j)(1) and (2). Dry Space/Painting Area, second floor Storage area; On or about 22 January 2015 and times prior thereto the second floor storage containers had an 80 inch unguarded portion. this condition exposed employees to a 10 foot fall hazard.

Date of last update: 24 Jan 2025

Sources: State of Alaska - Department of Commerce, Community, and Economic Development