346540099
|
1032100
|
2023-02-28
|
MILE 4, CAPTAINS BAY RD., DUTCH HARBOR, AK, 99692
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2023-02-28
|
Case Closed |
2023-07-25
|
|
346539265
|
1032100
|
2023-02-28
|
MILE 4, CAPTAINS BAY RD., DUTCH HARBOR, AK, 99692
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Health
|
Close Conference |
2023-02-28
|
Case Closed |
2023-04-19
|
|
345848675
|
1032100
|
2022-03-22
|
MILE 4 CAPTAINS BAY RD., DUTCH HARBOR, AK, 99692
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2022-03-22
|
Case Closed |
2022-06-06
|
|
344704143
|
1032100
|
2020-03-11
|
SOUTH DOCK, OSI DOCK, DUTCH HARBOR, AK, 99692
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Health
|
Close Conference |
2020-03-11
|
Emphasis |
L: FISH, P: FISH
|
Case Closed |
2020-04-16
|
Related Activity
Type |
Inspection |
Activity Nr |
1470454 |
Safety |
Yes |
|
|
344704549
|
1032100
|
2020-03-11
|
MILE 4 , CAPTAINS BAY RD., DUTCH HARBOR, AK, 99692
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2020-03-11
|
Emphasis |
L: LONGSHORE, P: LONGSHORE
|
Case Closed |
2020-06-26
|
Related Activity
Type |
Inspection |
Activity Nr |
1470408 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1470451 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1470414 |
Health |
Yes |
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19100305 G01 IV A |
Issuance Date |
2020-05-06 |
Abatement Due Date |
2020-06-02 |
Current Penalty |
2271.0 |
Initial Penalty |
3785.0 |
Final Order |
2020-06-11 |
Nr Instances |
4 |
Nr Exposed |
5 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure. (a) Offshore Systems Terminal - South Dock - On or about March 11, 2020 and at times prior thereto, employees were exposed to electrical shock in that 110VDC extension cords were used in lieu of permanently installed wiring to provide power to the auto-winders. |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19100305 G01 IV D |
Issuance Date |
2020-05-06 |
Abatement Due Date |
2020-06-02 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2020-06-11 |
Nr Instances |
4 |
Nr Exposed |
5 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.305(g)(1)(iv)(D): Flexible cords and cables were attached to building surfaces. (a) Offshore Systems Terminal - South Dock - On or about March 11, 2020 and at times prior thereto, employees were exposed to electrical shock in that 110VDC extension cords were used and fastened to the building's structure with zip ties, in lieu of permanently installed wiring to provide power to the auto-winders. |
|
|
342944121
|
1032100
|
2018-02-08
|
P.O. BOX 920427, DUTCH HARBOR, AK, 99692
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Health
|
Close Conference |
2018-02-08
|
Emphasis |
L: LONGSHORE, P: LONGSHORE
|
Case Closed |
2018-04-23
|
Related Activity
Type |
Inspection |
Activity Nr |
1294403 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Repeat |
Standard Cited |
19101200 F06 I |
Issuance Date |
2018-03-13 |
Abatement Due Date |
2018-04-10 |
Current Penalty |
258.0 |
Initial Penalty |
258.0 |
Final Order |
2018-04-10 |
Nr Instances |
1 |
Nr Exposed |
4 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(f)(6)(i): Except as provided in 29 CFR 1910.1200(f)(7) and 29 CFR 1910.1200(f)(8), the employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the information required by 29 CFR 1910.1200(f)(1)(i) through 29 CFR 1910.1200(f)(1)(v) Maintenance Shop: On or about 08 February 2018 and times prior thereto, there was an unlabeled container in the fluid supply area. This condition exposed employees to delays in getting proper first aid and knowing correct PPE for the type of chemical. Offshore Systems, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1910.1200(f)(6)(i), which was contained in OSHA inspection number 1041869, citation number 1, item number 2 and was affirmed as a final order on 20 April 2015, with respect to a workplace located at Offshore Systems, Inc., Captains Bay Road, Dutch Harbor, Alaska. |
|
Citation ID |
01002 |
Citaton Type |
Repeat |
Standard Cited |
19170095 C |
Issuance Date |
2018-03-13 |
Abatement Due Date |
2018-04-10 |
Current Penalty |
258.0 |
Initial Penalty |
258.0 |
Final Order |
2018-04-10 |
Nr Instances |
2 |
Nr Exposed |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1917.95(c): The employer did not provide well maintained emergency bathing, eye washing or other facilities where employees were exposed to hazardous substances. (a) Maintenance shop, vehicle bay area: On or about 08 February 2018 and times prior thereto, the emergency eyewash station was not readily available. Unit required servicing. This condition exposed delays in employees to utilize the eyewash. (b) JSA Room: On or about 08 February 2018 and times prior thereto, the emergency eyewash stations was not serviced. This condition exposed delays in employees to utilize the eyewash. Offshore Systems, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1917.95(c), which was contained in OSHA inspection number 1041869, citation number 1, item number 1 and was affirmed as a final order on 20 April 2015, with respect to a workplace located at Offshore Systems, Inc., Captains Bay Road, Dutch Harbor, Alaska. |
|
|
342944030
|
1032100
|
2018-02-08
|
P.O. BOX 920427, DUTCH HARBOR, AK, 99692
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2018-02-08
|
Emphasis |
L: LONGSHORE, P: LONGSHORE
|
Case Closed |
2018-04-17
|
Related Activity
Type |
Inspection |
Activity Nr |
1294412 |
Health |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100334 A02 I |
Issuance Date |
2018-03-13 |
Current Penalty |
2000.0 |
Initial Penalty |
3880.0 |
Final Order |
2018-04-09 |
Nr Instances |
1 |
Nr Exposed |
17 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.334(a)(2)(i): Portable cord and plug connected equipment and flexible cord sets (extension cords) were not visually inspected before use on any shift for external defects (such as loose parts, deformed and missing pins, or damage to outer jacket or insulation) and for evidence of possible internal damage (such as pinched or crushed outer jacket). 450 Shed, on or about 08 February 2018 and times prior thereto; a 50-foot black heavy duty extension cord had damage to the outer protective jacket. This condition exposed employees to an electrical shock hazard. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19170111 B |
Issuance Date |
2018-03-13 |
Abatement Due Date |
2018-04-10 |
Current Penalty |
2000.0 |
Initial Penalty |
3880.0 |
Final Order |
2018-04-09 |
Nr Instances |
1 |
Nr Exposed |
4 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1917.111(b): Maximum safe load limits, in pounds per square foot (kilograms per square meter), of floors elevated above ground level, and pier structures over the water were not conspicuously posted in all cargo areas. Maintenance shop; on or about 08 February 2018 and times prior thereto, the maximum safe load limits was not conspicuously posted on the mezzanine. This condition exposed employees to a struck by hazard. |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19170151 B03 |
Issuance Date |
2018-03-13 |
Abatement Due Date |
2018-04-10 |
Current Penalty |
2000.0 |
Initial Penalty |
3880.0 |
Final Order |
2018-04-09 |
Nr Instances |
2 |
Nr Exposed |
4 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1917.151(b)(3): Fixed machinery was not secured to prevent shifting. Maintenance shop, on or about 08 February 2018 and times prior thereto, two instances were noted where floor drill presses where not securely anchored: a. Welding and fabrication area; a 20-inch, Westward Drill Press, 12-Speed, Model 1KEN7, Serial number unknown was not securely anchored to prevent movement b. Southwest bay; a 15-inch Jet Floor Drill Press, Model J-2500, Serial Number 17021687 was not securely anchored to prevent movement. This condition exposed employees to a struck by hazard. |
|
Citation ID |
01004 |
Citaton Type |
Serious |
Standard Cited |
19170156 A09 |
Issuance Date |
2018-03-13 |
Abatement Due Date |
2018-04-10 |
Current Penalty |
3300.0 |
Initial Penalty |
6467.0 |
Final Order |
2018-04-09 |
Nr Instances |
1 |
Nr Exposed |
64 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1917.156(a)(9): Liquid fuel dispensing devices, such as pumps, were not mounted on a concrete island or otherwise protected against collision damage. Yard area adjacent to maintenance shop; on or about 08 February 2018 and times prior thereto, a 500-gallon gasoline dispensing station was not protected from vehicular traffic. Dispensing station is located adjacent to a moderate vehicular traffic area. This condition exposed employees to fire and explosion hazards. |
|
Citation ID |
02001 |
Citaton Type |
Repeat |
Standard Cited |
19100305 B01 II |
Issuance Date |
2018-03-13 |
Abatement Due Date |
2018-04-10 |
Current Penalty |
6700.0 |
Initial Penalty |
7760.0 |
Final Order |
2018-04-09 |
Nr Instances |
4 |
Nr Exposed |
4 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed. Maintenance shop and JSA room; on or about 08 February 2018 and time prior thereto, four instances were noted where electrical opening were not effectively closed. a. Maintenance shop northeast area, a four-place energized outlet box was missing a knockout plug on the left hand side. b. Maintenance shop southwest area, a two-place energized outlet with a rocker switch was missing the knockout plug on the top of the outlet box. c. JSA room, south wall two energized electrical outlets were missing the faceplates. This condition exposed employees to an electrical shock hazard. Offshore Systems Inc., was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.305(b)(1)(ii) which was contained in OSHA inspection number 1041808, citation number 1, item number 3 and was affirmed as a final order on 20 April 2015, with respect to a workplace located at OSI Dock, Captains Bay Road in Dutch Harbor, AK. |
|
Citation ID |
03001 |
Citaton Type |
Other |
Standard Cited |
19100303 B07 IV |
Issuance Date |
2018-03-13 |
Abatement Due Date |
2018-04-10 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2018-04-09 |
Nr Instances |
3 |
Nr Exposed |
17 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.303(b)(7)(iv): Electrical equipment had damaged parts that may adversely affect safe operation or mechanical strength of the equipment, such as parts that are broken, bent, cut, or deteriorated by corrosion, chemical action, or overheating. 450 Shed, adjacent to the man door leading to the dock; on or about 08 February 2018 and times prior thereto; three energized rocker switches were damaged. Switches labeled South, Center, and North were broken. This condition exposed employees to damaged electrical equipment. |
|
Citation ID |
03002 |
Citaton Type |
Other |
Standard Cited |
19170122 A |
Issuance Date |
2018-03-13 |
Abatement Due Date |
2018-04-10 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2018-04-09 |
Nr Instances |
1 |
Nr Exposed |
4 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1917.122(a): Employee exits were not clearly marked. North area of maintenance shop; on or about 08 February and time prior thereto, the employer did not ensure that exit signs were posted along the exit route. The door way leading to the north exit route was not marked. This condition exposed employees to delays in exiting the building causing smoke inhalation and fire hazards. |
|
|
340418698
|
1032700
|
2015-02-12
|
OSI DOCK CAPTAIN'S BAY ROAD, DUTCH HARBOR, AK, 99692
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Health
|
Close Conference |
2015-02-12
|
Emphasis |
L: LONGSHORE, P: LONGSHORE
|
Case Closed |
2015-05-15
|
Related Activity
Type |
Inspection |
Activity Nr |
1041870 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1041808 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19170095 C |
Issuance Date |
2015-03-24 |
Abatement Due Date |
2015-04-21 |
Current Penalty |
2066.0 |
Initial Penalty |
2066.0 |
Final Order |
2015-04-20 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1917.95(c): The employer did not provide well maintained emergency bathing, eye washing or other facilities where employees were exposed to hazardous substances. OSI Dock, Maintenance shop: On or about 12 February 2015 and times prior thereto, the emergency eyewash station was blocked with a supplies and a bicycle. This condition exposed delays in employees to utilize the eyewash. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100095 D01 |
Issuance Date |
2015-03-24 |
Abatement Due Date |
2015-04-21 |
Current Penalty |
0.0 |
Initial Penalty |
2066.0 |
Final Order |
2015-04-20 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.95(d)(1): When information indicated that any employee's exposure equaled or exceed the 8-hour time-weighted average of 85 decibels, the employer did not develop and implement a monitoring program: OSI Dock, Freezer : On or about 12 February 2015 and times prior thereto, hearing conservation monitoring had not been completed for the freezer. This condition allowed for employees to not have the knowledge of noise hazardous conditions and where to wear hearing protection while in the freezer. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19101200 F06 I |
Issuance Date |
2015-03-24 |
Abatement Due Date |
2015-04-21 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2015-04-20 |
Nr Instances |
3 |
Nr Exposed |
22 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(f)(6)(i): Except as provided in 29 CFR 1910.1200(f)(7) and 29 CFR 1910.1200(f)(8), the employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the information required by 29 CFR 1910.1200(f)(1)(i) through 29 CFR 1910.1200(f)(1)(v): OSI Dock Maintenance shop: On or about 12 February 2015, and times prior thereto, there was an unlabeled container in the work area. This exposed employees to delays in getting proper first aid and knowing the correct PPE for the type of chemical. |
|
|
340418706
|
1032100
|
2015-02-12
|
M/V COASTAL MERCHANT OSI DOCK, DUTCH HARBOR, AK, 99692
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2015-02-12
|
Emphasis |
L: LONGSHORE, P: LONGSHORE
|
Case Closed |
2015-05-19
|
Related Activity
Type |
Inspection |
Activity Nr |
1041869 |
Health |
Yes |
|
Type |
Inspection |
Activity Nr |
1041808 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19170043 C04 |
Issuance Date |
2015-03-24 |
Abatement Due Date |
2015-04-21 |
Current Penalty |
1239.6 |
Initial Penalty |
2066.0 |
Final Order |
2015-04-20 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1917.43(c)(4): Braking systems on powered industrial trucks were not operable and/or in safe condition OSI Dock, M/V Coastal Merchant: On or about 12 February 2015 and times prior thereto, the Nissan 90, #F21 forklift was been operated to offload the M/V Coastal Merchant with an inoperative emergency brake. This condition exposed employees to a struck by hazard. |
|
|
340418086
|
1032100
|
2015-02-12
|
OSI DOCK CAPTAIN'S BAY ROAD, DUTCH HARBOR, AK, 99692
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2015-02-12
|
Emphasis |
L: LONGSHORE, P: LONGSHORE
|
Case Closed |
2015-05-11
|
Related Activity
Type |
Inspection |
Activity Nr |
1041870 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1041869 |
Health |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100212 B |
Issuance Date |
2015-03-24 |
Abatement Due Date |
2015-04-21 |
Current Penalty |
1239.6 |
Initial Penalty |
2066.0 |
Final Order |
2015-04-20 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.212(b): Machine(s) designed for fixed location(s) were not securely anchored to prevent walking or moving OSI Dock, Maintenance Shop, Fabrication Bay: On or about 12 February 2015 and times prior thereto, the Baldor, 3600 RPM, Serial Number X1002207012, Bench Grinder was not secured to the bench. This condition exposed employees to a struck by hazard. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100215 A04 |
Issuance Date |
2015-03-24 |
Abatement Due Date |
2015-04-21 |
Current Penalty |
1239.6 |
Initial Penalty |
2066.0 |
Final Order |
2015-04-20 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.215(a)(4): Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one eighth inch. OSI Dock, Maintenance Shop, Fabrication Bay: On or about 12 February 2015 and times prior thereto, the Baldor, 3600 RPM, Serial Number X1002207012, Bench Grinder work rest measured 1.4' from the abrasive wheel. This condition exposed employees to a struck by hazard. |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19100305 B01 II |
Issuance Date |
2015-03-24 |
Abatement Due Date |
2015-04-21 |
Current Penalty |
1239.6 |
Initial Penalty |
2066.0 |
Final Order |
2015-04-20 |
Nr Instances |
2 |
Nr Exposed |
2 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed. (a) OSI Dock, Maintenance Shop,1st Bay: On or about 12 February 2015 and times prior thereto, the 120 volt electrical light switch by the roll up door was missing a knock-out. this condition exposed employees to an electrical shock and burn hazard. (b) OSI Dock, Maintenance Shop, Fabrication Bay: On or about 12 February 2015 and times prior thereto, the 120 volt junction box by the roll up door was missing a knock-out. this condition exposed employees to an electrical shock and burn hazard. |
|
Citation ID |
01004 |
Citaton Type |
Serious |
Standard Cited |
19100305 G02 II |
Issuance Date |
2015-03-24 |
Abatement Due Date |
2015-04-21 |
Current Penalty |
1239.6 |
Initial Penalty |
2066.0 |
Final Order |
2015-04-20 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.305(g)(2)(ii): Flexible cords were not used only in continuous lengths without splice or tap. OSI Dock, Maintenance Shop,1st Bay: On or about 12 February 2015 and times prior thereto, the 120 volt, 15 amp Skilsaw electrical cord was cut and spliced together with black electrician tape. This condition exposed employees to an electrical shock and burn hazard. |
|
Citation ID |
01005 |
Citaton Type |
Serious |
Standard Cited |
19170026 F |
Issuance Date |
2015-03-24 |
Abatement Due Date |
2015-04-21 |
Current Penalty |
1239.6 |
Initial Penalty |
2066.0 |
Final Order |
2015-04-20 |
Nr Instances |
1 |
Nr Exposed |
5 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1917.26(f): A US Coast Guard approved 30 inch life ring, with at least 90 feet of line attached, was not available at readily accessible points at each waterside work area where the employees' work exposed them to the hazard of drowning. Osi Dock, crane pad: On or about 12 February 2015 and times prior thereto, the life ring located at the crane pad only had approximately 60 feet of rope attached. This condition exposed employees to delays in rendering aid. |
|
|
331921148
|
1032100
|
2012-02-14
|
MILE FOUR CAPTAINS BAY ROAD P.O. BOX 920427, DUTCH HARBOR, AK, 99692
|
|
Inspection Type |
Prog Related |
Scope |
Partial |
Safety/Health |
Safety |
Close Conference |
2012-02-14 |
Emphasis |
N: TRENCH |
Case Closed |
2012-08-10 |
|
307505941
|
1032100
|
2010-02-03
|
MAIN OSI DOCK, DUTCH HARBOR, AK, 99692
|
|
Inspection Type |
Planned |
Scope |
Partial |
Safety/Health |
Safety |
Close Conference |
2010-02-10 |
Emphasis |
S: POWERED IND VEHICLE, S: STRUCK-BY |
Case Closed |
2010-05-21 |
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100178 L01 I |
Issuance Date |
2010-03-03 |
Abatement Due Date |
2010-04-05 |
Current Penalty |
720.0 |
Initial Penalty |
1200.0 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
02 |
|
|
307505735
|
1032100
|
2010-02-03
|
SOUTH DOCK, OSI DOCK, DUTCH HARBOR, AK, 99692
|
|
Inspection Type |
Planned |
Scope |
Complete |
Safety/Health |
Health |
Close Conference |
2010-02-10 |
Case Closed |
2010-06-18 |
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19101200 E01 |
Issuance Date |
2010-04-12 |
Abatement Due Date |
2010-05-13 |
Current Penalty |
540.0 |
Initial Penalty |
900.0 |
Nr Instances |
1 |
Nr Exposed |
4 |
Gravity |
01 |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19101200 G01 |
Issuance Date |
2010-04-12 |
Abatement Due Date |
2010-05-13 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
01 |
|
Citation ID |
01001C |
Citaton Type |
Serious |
Standard Cited |
19101200 H01 |
Issuance Date |
2010-04-12 |
Abatement Due Date |
2010-05-13 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
01 |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19170026 D01 |
Issuance Date |
2010-04-12 |
Abatement Due Date |
2010-06-21 |
Current Penalty |
900.0 |
Initial Penalty |
1500.0 |
Nr Instances |
1 |
Nr Exposed |
36 |
Gravity |
03 |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19170030 A02 |
Issuance Date |
2010-04-12 |
Abatement Due Date |
2010-06-21 |
Current Penalty |
540.0 |
Initial Penalty |
900.0 |
Nr Instances |
1 |
Nr Exposed |
38 |
Gravity |
01 |
|
Citation ID |
01004 |
Citaton Type |
Serious |
Standard Cited |
19170152 D01 VII |
Issuance Date |
2010-04-12 |
Abatement Due Date |
2010-04-22 |
Current Penalty |
540.0 |
Initial Penalty |
900.0 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
01 |
|
Citation ID |
01005 |
Citaton Type |
Serious |
Standard Cited |
19170154 |
Issuance Date |
2010-04-12 |
Abatement Due Date |
2010-04-22 |
Current Penalty |
720.0 |
Initial Penalty |
1200.0 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
02 |
|
Citation ID |
02001 |
Citaton Type |
Serious |
Standard Cited |
19170157 I |
Issuance Date |
2010-04-12 |
Abatement Due Date |
2010-06-21 |
Current Penalty |
1500.0 |
Initial Penalty |
3000.0 |
Nr Instances |
4 |
Nr Exposed |
3 |
Gravity |
03 |
|
Citation ID |
03001 |
Citaton Type |
Other |
Standard Cited |
19040029 A |
Issuance Date |
2010-04-12 |
Abatement Due Date |
2010-05-13 |
Current Penalty |
600.0 |
Initial Penalty |
1000.0 |
Nr Instances |
3 |
Nr Exposed |
1 |
Gravity |
00 |
|
Citation ID |
03002 |
Citaton Type |
Other |
Standard Cited |
19100134 H02 I |
Issuance Date |
2010-04-12 |
Abatement Due Date |
2010-04-22 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
01 |
|
|
307505727
|
1032100
|
2010-02-03
|
SOUTH DOCK, OSI DOCK, DUTCH HARBOR, AK, 99692
|
|
Inspection Type |
Planned |
Scope |
Complete |
Safety/Health |
Safety |
Close Conference |
2010-02-10 |
Emphasis |
S: FALL FROM HEIGHT, S: ELECTRICAL, S: POWERED IND VEHICLE, S: STRUCK-BY |
Case Closed |
2010-06-18 |
Related Activity
Type |
Inspection |
Activity Nr |
307505735 |
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19100178 L01 I |
Issuance Date |
2010-04-12 |
Abatement Due Date |
2010-04-16 |
Current Penalty |
1800.0 |
Initial Penalty |
3000.0 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
10 |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19100178 L06 |
Issuance Date |
2010-04-12 |
Abatement Due Date |
2010-05-13 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
03 |
|
Citation ID |
01001C |
Citaton Type |
Serious |
Standard Cited |
19170043 C05 |
Issuance Date |
2010-04-12 |
Abatement Due Date |
2010-05-13 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
03 |
|
Citation ID |
01002A |
Citaton Type |
Serious |
Standard Cited |
19100215 D03 |
Issuance Date |
2010-04-12 |
Abatement Due Date |
2010-04-16 |
Current Penalty |
900.0 |
Initial Penalty |
1500.0 |
Nr Instances |
1 |
Nr Exposed |
6 |
Gravity |
03 |
|
Citation ID |
01002B |
Citaton Type |
Serious |
Standard Cited |
19170151 G01 |
Issuance Date |
2010-04-12 |
Abatement Due Date |
2010-05-13 |
Nr Instances |
1 |
Nr Exposed |
6 |
Gravity |
03 |
|
Citation ID |
01002C |
Citaton Type |
Serious |
Standard Cited |
19170151 G04 |
Issuance Date |
2010-04-12 |
Abatement Due Date |
2010-05-13 |
Nr Instances |
1 |
Nr Exposed |
6 |
Gravity |
03 |
|
Citation ID |
01003A |
Citaton Type |
Serious |
Standard Cited |
19100305 D02 |
Issuance Date |
2010-04-12 |
Abatement Due Date |
2010-04-16 |
Current Penalty |
1800.0 |
Initial Penalty |
3000.0 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
10 |
|
Citation ID |
01003B |
Citaton Type |
Serious |
Standard Cited |
19100303 F02 |
Issuance Date |
2010-04-12 |
Abatement Due Date |
2010-05-13 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
03 |
|
Citation ID |
01003C |
Citaton Type |
Serious |
Standard Cited |
19100303 G02 II |
Issuance Date |
2010-04-12 |
Abatement Due Date |
2010-05-13 |
Nr Instances |
1 |
Nr Exposed |
6 |
Gravity |
03 |
|
Citation ID |
01003D |
Citaton Type |
Serious |
Standard Cited |
19100305 B02 I |
Issuance Date |
2010-04-12 |
Abatement Due Date |
2010-05-13 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
01 |
|
Citation ID |
01003E |
Citaton Type |
Serious |
Standard Cited |
19100305 J04 V |
Issuance Date |
2010-04-12 |
Abatement Due Date |
2010-05-13 |
Nr Instances |
1 |
Nr Exposed |
6 |
Gravity |
02 |
|
Citation ID |
01004 |
Citaton Type |
Serious |
Standard Cited |
19170111 D |
Issuance Date |
2010-04-12 |
Abatement Due Date |
2010-05-13 |
Current Penalty |
540.0 |
Initial Penalty |
900.0 |
Nr Instances |
3 |
Nr Exposed |
6 |
Gravity |
01 |
|
Citation ID |
01005A |
Citaton Type |
Serious |
Standard Cited |
19170119 F05 |
Issuance Date |
2010-04-12 |
Abatement Due Date |
2010-05-13 |
Current Penalty |
720.0 |
Initial Penalty |
1200.0 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
02 |
|
Citation ID |
01005B |
Citaton Type |
Serious |
Standard Cited |
19170119 E01 |
Issuance Date |
2010-04-12 |
Abatement Due Date |
2010-05-13 |
Nr Instances |
2 |
Nr Exposed |
6 |
Gravity |
01 |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19100212 B |
Issuance Date |
2010-04-12 |
Abatement Due Date |
2010-05-13 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
01 |
|
Citation ID |
02002 |
Citaton Type |
Other |
Standard Cited |
19170122 C |
Issuance Date |
2010-04-12 |
Abatement Due Date |
2010-05-13 |
Nr Instances |
1 |
Nr Exposed |
6 |
Gravity |
01 |
|
|
301495347
|
1032100
|
1999-02-08
|
MILE 4 CAPTAINS BAY ROAD, DUTCH HARBOR, AK, 99692
|
|
Inspection Type |
Planned |
Scope |
Complete |
Safety/Health |
Safety |
Close Conference |
1999-02-08 |
Case Closed |
1999-10-12 |
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100303 G02 I |
Issuance Date |
1999-03-15 |
Abatement Due Date |
1999-03-25 |
Current Penalty |
1125.0 |
Initial Penalty |
1125.0 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
03 |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19170112 B01 |
Issuance Date |
1999-03-15 |
Abatement Due Date |
1999-04-01 |
Current Penalty |
1125.0 |
Initial Penalty |
1125.0 |
Nr Instances |
2 |
Nr Exposed |
1 |
Gravity |
03 |
|
Citation ID |
02001A |
Citaton Type |
Other |
Standard Cited |
19170026 D07 |
Issuance Date |
1999-03-15 |
Abatement Due Date |
1999-03-25 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
01 |
|
Citation ID |
02001B |
Citaton Type |
Other |
Standard Cited |
19170026 D03 |
Issuance Date |
1999-03-15 |
Abatement Due Date |
1999-03-25 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
01 |
|
Citation ID |
02001C |
Citaton Type |
Other |
Standard Cited |
19170026 D04 |
Issuance Date |
1999-03-15 |
Abatement Due Date |
1999-03-25 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
01 |
|
Citation ID |
02002 |
Citaton Type |
Other |
Standard Cited |
19100305 B01 |
Issuance Date |
1999-03-15 |
Abatement Due Date |
1999-03-19 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
01 |
|
Citation ID |
02003A |
Citaton Type |
Other |
Standard Cited |
19101200 F05 I |
Issuance Date |
1999-03-15 |
Abatement Due Date |
1999-03-19 |
Nr Instances |
3 |
Nr Exposed |
1 |
Gravity |
01 |
|
Citation ID |
02003B |
Citaton Type |
Other |
Standard Cited |
19101200 F05 II |
Issuance Date |
1999-03-15 |
Abatement Due Date |
1999-03-19 |
Nr Instances |
3 |
Nr Exposed |
1 |
Gravity |
01 |
|
Citation ID |
02004 |
Citaton Type |
Other |
Standard Cited |
19170012 |
Issuance Date |
1999-03-15 |
Abatement Due Date |
1999-03-19 |
Nr Instances |
2 |
Nr Exposed |
1 |
Gravity |
01 |
|
|
107107237
|
1032100
|
1992-01-07
|
SOUTH DOCK, OSI DOCK, DUTCH HARBOR, AK, 99692
|
|
Inspection Type |
Unprog Rel |
Scope |
Partial |
Safety/Health |
Safety |
Close Conference |
1992-01-07 |
Case Closed |
1992-04-20 |
Related Activity
Type |
Inspection |
Activity Nr |
107107229 |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19170124 A |
Issuance Date |
1992-04-09 |
Abatement Due Date |
1992-04-17 |
Current Penalty |
525.0 |
Initial Penalty |
525.0 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
01 |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19180074 A05 |
Issuance Date |
1992-04-09 |
Abatement Due Date |
1992-04-12 |
Current Penalty |
875.0 |
Initial Penalty |
875.0 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
03 |
|
|