342943776
|
1032100
|
2018-02-09
|
F/V ALASKA WARRIOR OSI DOCK, DUTCH HARBOR, AK, 99692
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2018-02-09
|
Emphasis |
L: FISH, P: FISH
|
Case Closed |
2018-06-06
|
Related Activity
Type |
Inspection |
Activity Nr |
1294392 |
Health |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100215 B09 |
Issuance Date |
2018-03-14 |
Abatement Due Date |
2018-04-11 |
Current Penalty |
3000.0 |
Initial Penalty |
4398.0 |
Final Order |
2018-04-16 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch. F/V Alaska Warrior, OSI Dock, Factor Shop; on or about 09 February 2018 and times prior thereto; the tongue guard on a six-inch Baldor Bench Grinder, Model 73060, Serial Number W0806142315 was missing. This condition exposed employees to a caught in hazard. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100253 B04 III |
Issuance Date |
2018-03-14 |
Abatement Due Date |
2018-04-11 |
Current Penalty |
4000.0 |
Initial Penalty |
5497.0 |
Final Order |
2018-04-16 |
Nr Instances |
7 |
Nr Exposed |
54 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet. F/V Alaska Warrior, OSI Dock, Deck starboard adjacent to engine room entrance; on or about 09 February 2018 and times prior thereto; four oxygen cylinders and three acetylene cylinders were not separated by at least 20-feet or by a noncombustible barrier. This condition exposed employees to fire and explosion hazards. |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19150055 A01 |
Issuance Date |
2018-03-14 |
Abatement Due Date |
2018-04-11 |
Current Penalty |
2000.0 |
Initial Penalty |
3298.0 |
Final Order |
2018-04-16 |
Nr Instances |
3 |
Nr Exposed |
53 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1915.55(a)(1): Valve protection caps on gas Welding and cutting cylinders were not in place or secure. F/V Alaska Warrior, OSI Dock, Deck starboard adjacent to engine room entrance; on or about 09 February 2018 and times prior thereto; three instances were noted where welding and cutting cylinders did not have the protective caps installed: a. Deck starboard adjacent to engine room entrance; two oxygen cylinders were missing the protective caps. b. Deck starboard adjacent to engine room entrance; one acetylene cylinder was missing its protective cap. This condition exposed employees to fire and explosion hazards. |
|
|
342943925
|
1032100
|
2018-02-09
|
F/V ALASKA WARRIOR OSI DOCK, DUTCH HARBOR, AK, 99692
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Health
|
Close Conference |
2018-02-09
|
Emphasis |
L: FISH, P: FISH
|
Case Closed |
2018-06-06
|
Related Activity
Type |
Inspection |
Activity Nr |
1294377 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100134 H02 I |
Issuance Date |
2018-03-14 |
Abatement Due Date |
2018-04-11 |
Current Penalty |
2000.0 |
Initial Penalty |
3298.0 |
Final Order |
2018-04-17 |
Nr Instances |
2 |
Nr Exposed |
4 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.134(h)(2)(i): Respirators were not stored to protect them from damage, contamination, dust, sunlight, extreme temperatures, excessive moisture, and damaging chemicals or were not packed or stored to prevent deformation of the facepiece and exhalation valve OSI Dock, F/V Alaska Warrior, Deck: On or about 09 February 2018 and times prior thereto, Respirators were not properly stored for protection. This exposed employees to respiratory hazards. |
|
|
338912090
|
1032100
|
2013-02-16
|
F/T SEAFISHER OSI DOCK, DUTCH HARBOR, AK, 99692
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2013-02-16
|
Emphasis |
L: FISH, N: AMPUTATE, P: FISH
|
Case Closed |
2013-04-10
|
Related Activity
Type |
Inspection |
Activity Nr |
891216 |
Health |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100023 A07 |
Issuance Date |
2013-03-12 |
Abatement Due Date |
2013-04-05 |
Current Penalty |
2343.6 |
Initial Penalty |
2520.0 |
Final Order |
2013-04-03 |
Nr Instances |
1 |
Nr Exposed |
20 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.23(a)(7): Every temporary floor opening shall have standard railings, or shall be constantly attended by someone. Main deck area: On or about 16 February 1023 and times prior thereto, the 8 foot by 8 foot hatch was open with loose rope railings installed. This condition exposed employees to a 18 foot fall hazard. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100037 A04 |
Issuance Date |
2013-03-12 |
Abatement Due Date |
2013-04-05 |
Current Penalty |
0.0 |
Initial Penalty |
1890.0 |
Final Order |
2013-04-03 |
Nr Instances |
2 |
Nr Exposed |
54 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.37(a)(4): Safeguard(s) designed to protect employees during an emergency (e.g., sprinkler systems, alarm systems, fire doors, exit lighting), were not in proper working order at all times. On or about 16 February 2013 and times prior thereto, the emergency exit lighting for the galley and engine room were inoperative. This condition exposed employees to delays in existing the vessel causing smoke inhalation and fire hazards. |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19150114 B |
Issuance Date |
2013-03-12 |
Abatement Due Date |
2013-04-05 |
Current Penalty |
1757.7 |
Initial Penalty |
1890.0 |
Final Order |
2013-04-03 |
Nr Instances |
3 |
Nr Exposed |
6 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1915.114(b): Chain falls shall be regularly inspected to ensure that they are safe, particular attention being given to the lift chain, pinion, sheaves and hooks for distortion and wear. Pull-lifts shall be regularly inspected to ensure that they are safe, particular attention being given to the ratchet, pawl, chain and hooks for distortion and wear. Engine room, Starboard side passageway: On or about 16 February 2013 and times prior thereto, three Dayton hand chain hoists were missing safety latches on the hooks. This condition exposed employees to a struck by hazard. |
|
Citation ID |
01004 |
Citaton Type |
Serious |
Standard Cited |
19150134 B |
Issuance Date |
2013-03-12 |
Abatement Due Date |
2013-04-05 |
Current Penalty |
1757.7 |
Initial Penalty |
1890.0 |
Final Order |
2013-04-03 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1915.134(b): Work rests were not kept a distance not to exceed 1/8 inch from the surface of the wheel. Machine shop: On or about 16 February 2013 and times prior thereto, the Jet 10" Bench Grinder, model number JBG-10A, work rest measured 3/4" from the wheel. This condition exposed employees to a caught in hazard. |
|
Citation ID |
01005 |
Citaton Type |
Serious |
Standard Cited |
19180051 D03 |
Issuance Date |
2013-03-12 |
Abatement Due Date |
2013-04-05 |
Current Penalty |
0.0 |
Initial Penalty |
1890.0 |
Final Order |
2013-04-03 |
Nr Instances |
1 |
Nr Exposed |
7 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1918.51(d)(3): Wire rope and/or wire rope slings exhibiting defects or conditions specified in 29 CFR 1918.62(b)(3)(i) through (vi) were not removed from use. Upper deck powered winch, Gilson wire rope: On or about 16 February 2013 and times prior thereto, the 3/4" wire rope had evidence of bird caging. This condition exposed employees to a struck by hazard. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19040032 B06 |
Issuance Date |
2013-03-12 |
Abatement Due Date |
2013-04-05 |
Current Penalty |
567.0 |
Initial Penalty |
630.0 |
Final Order |
2013-04-03 |
Nr Instances |
1 |
Nr Exposed |
54 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1904.32(b)(6): The Summary of Work-Related Injuries and Illnesses (OSHA Form 300A or equivalent) for the previous year was not posted between February 1 and April 30. F/V Seafisher: On or about 16 February 2013 and times prior thereto, the OSHA 300A was not signed or posted for employees to review. |
|
|
338912165
|
1032100
|
2013-02-16
|
F/T SEAFISHER OSI DOCK, DUTCH HARBOR, AK, 99692
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Health
|
Close Conference |
2013-02-16
|
Emphasis |
L: FISH, N: AMPUTATE, P: FISH
|
Case Closed |
2013-04-10
|
Related Activity
Type |
Inspection |
Activity Nr |
891209 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Other |
Standard Cited |
19100132 D01 I |
Issuance Date |
2013-03-12 |
Abatement Due Date |
2013-04-05 |
Current Penalty |
1134.0 |
Initial Penalty |
1890.0 |
Final Order |
2013-04-03 |
Nr Instances |
1 |
Nr Exposed |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.132(d)(1)(i): The employer did not select and have each affected employee use, the types of personal protective equipment that would protect the affected employee(s) from the hazards identified in the hazard assessment: F/T Seafisher, Galley: On or about 16 February 2013 and times prior thereto, the cook did not have nor was required to use cut resistant gloves while using knives in the galley for food preparation. This condition exposed the employee to laceration hazards. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100151 C |
Issuance Date |
2013-03-12 |
Abatement Due Date |
2013-04-05 |
Current Penalty |
1134.0 |
Initial Penalty |
1890.0 |
Final Order |
2013-04-03 |
Nr Instances |
1 |
Nr Exposed |
5 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use: F/T Seafisher Factory: On or about 16 February 2013 and times prior thereto, Eye wash stations were not established while employees were using Super Red Plus. This condition exposed employees to chemical hazards in the event of eye or face exposure to corrosives while cleaning the factory. |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19150089 C07 II |
Issuance Date |
2013-03-12 |
Abatement Due Date |
2013-04-05 |
Current Penalty |
1512.0 |
Initial Penalty |
2520.0 |
Final Order |
2013-04-03 |
Nr Instances |
1 |
Nr Exposed |
36 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1915.89(c)(7)(ii): The employer did not ensure the coordination process included a lockout/tags-plus coordinator and a lockout/tags-plus log. F/T Seafisher Factory, OSI Dock: On or about 16 February 2013 and times prior thereto, The lockout/tags-plus coordinator was not actively involved in the equipment de-energizing process and a lockout/tags-plus log was not established for Tokai headers locked out for routine servicing. This condition exposed employees to a caught in and amputation hazard. |
|
|
301494670
|
1032100
|
1998-05-01
|
F/T OCEAN PEACE, DUTCH HARBOR, AK, 99692
|
|
Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
1998-05-01
|
Emphasis |
L: FISH
|
Case Closed |
1998-12-07
|
Related Activity
Type |
Referral |
Activity Nr |
901873596 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
5A0001 |
Issuance Date |
1998-06-15 |
Abatement Due Date |
1998-06-23 |
Current Penalty |
578.0 |
Initial Penalty |
1750.0 |
Contest Date |
1998-06-29 |
Final Order |
1998-09-24 |
Nr Instances |
6 |
Nr Exposed |
49 |
Gravity |
05 |
Hazard |
ELECTRIC |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
5A0001 |
Issuance Date |
1998-06-15 |
Abatement Due Date |
1998-06-21 |
Current Penalty |
577.0 |
Initial Penalty |
1750.0 |
Contest Date |
1998-06-29 |
Final Order |
1998-09-24 |
Nr Instances |
1 |
Nr Exposed |
10 |
Gravity |
05 |
Hazard |
ELECTRIC |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
5A0001 |
Issuance Date |
1998-06-15 |
Abatement Due Date |
1998-06-22 |
Current Penalty |
330.0 |
Initial Penalty |
1000.0 |
Contest Date |
1998-06-29 |
Final Order |
1998-09-24 |
Nr Instances |
1 |
Nr Exposed |
5 |
Gravity |
02 |
Hazard |
ELECTRIC |
|
Citation ID |
01004 |
Citaton Type |
Serious |
Standard Cited |
5A0001 |
Issuance Date |
1998-06-15 |
Abatement Due Date |
1998-06-21 |
Current Penalty |
330.0 |
Initial Penalty |
1000.0 |
Contest Date |
1998-06-29 |
Final Order |
1998-09-24 |
Nr Instances |
2 |
Nr Exposed |
49 |
Gravity |
02 |
Hazard |
ELECTRIC |
|
Citation ID |
01005 |
Citaton Type |
Serious |
Standard Cited |
5A0001 |
Issuance Date |
1998-06-15 |
Abatement Due Date |
1998-06-23 |
Current Penalty |
578.0 |
Initial Penalty |
1750.0 |
Contest Date |
1998-06-29 |
Final Order |
1998-09-24 |
Nr Instances |
1 |
Nr Exposed |
49 |
Gravity |
05 |
Hazard |
LOCKOUT |
|
Citation ID |
01006 |
Citaton Type |
Serious |
Standard Cited |
19100038 A01 |
Issuance Date |
1998-06-15 |
Abatement Due Date |
1998-06-21 |
Current Penalty |
330.0 |
Initial Penalty |
1000.0 |
Contest Date |
1998-06-29 |
Final Order |
1998-09-24 |
Nr Instances |
1 |
Nr Exposed |
49 |
Gravity |
02 |
|
Citation ID |
01007 |
Citaton Type |
Serious |
Standard Cited |
19100213 G01 |
Issuance Date |
1998-06-15 |
Abatement Due Date |
1998-06-23 |
Current Penalty |
577.0 |
Initial Penalty |
1750.0 |
Contest Date |
1998-06-29 |
Final Order |
1998-09-24 |
Nr Instances |
1 |
Nr Exposed |
10 |
Gravity |
05 |
|
Citation ID |
01008A |
Citaton Type |
Serious |
Standard Cited |
19100215 A02 |
Issuance Date |
1998-06-15 |
Abatement Due Date |
1998-06-25 |
Current Penalty |
300.0 |
Initial Penalty |
900.0 |
Contest Date |
1998-06-29 |
Final Order |
1998-09-24 |
Nr Instances |
1 |
Nr Exposed |
10 |
Gravity |
01 |
|
Citation ID |
01008B |
Citaton Type |
Serious |
Standard Cited |
19100215 A04 |
Issuance Date |
1998-06-15 |
Abatement Due Date |
1998-06-25 |
Contest Date |
1998-06-29 |
Final Order |
1998-09-24 |
Nr Instances |
2 |
Nr Exposed |
10 |
Gravity |
02 |
|
Citation ID |
01008C |
Citaton Type |
Serious |
Standard Cited |
19100215 B09 |
Issuance Date |
1998-06-15 |
Abatement Due Date |
1998-06-25 |
Contest Date |
1998-06-29 |
Final Order |
1998-09-24 |
Nr Instances |
2 |
Nr Exposed |
10 |
Gravity |
02 |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19101200 E01 |
Issuance Date |
1998-06-15 |
Abatement Due Date |
1998-06-25 |
Contest Date |
1998-06-29 |
Final Order |
1998-09-24 |
Nr Instances |
1 |
Nr Exposed |
49 |
Gravity |
01 |
|
|