347025256
|
1032100
|
2023-10-02
|
1717 TIDEWATER RD. PORT OF ALASKA, ANCHORAGE, AK, 99501
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2023-10-02
|
Case Closed |
2024-02-06
|
|
347025322
|
1032100
|
2023-10-02
|
M/V ANCHORAGE MATSON ANCHORAGE PORT, ANCHORAGE, AK, 99501
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2023-10-02
|
Case Closed |
2024-02-06
|
|
347006595
|
1032100
|
2023-10-02
|
PORT OF ALASKA DOCK, ANCHORAGE, AK, 99501
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Health
|
Close Conference |
2023-10-02
|
Case Closed |
2023-10-11
|
|
346813470
|
1032100
|
2023-07-06
|
1717 TIDEWATER ROAD C/S KODIAK, ANCHORAGE, AK, 99501
|
|
Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2023-07-06
|
Case Closed |
2024-06-07
|
|
346359409
|
1032100
|
2022-10-20
|
1717 TIDEWATER ROAD PORT OF ANCHORAGE, ANCHORAGE, AK, 99501
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2022-10-20
|
Case Closed |
2023-05-01
|
|
345480321
|
1032100
|
2021-08-17
|
1717 TIDEWATER ROAD PORT OF ANCHORAGE, ANCHORAGE, AK, 99501
|
|
Inspection Type |
Complaint
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2021-08-17
|
Case Closed |
2022-01-28
|
|
344993555
|
1032100
|
2020-10-21
|
PIER 2 AND 3, KODIAK, AK, 99615
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2021-02-02
|
Emphasis |
L: LONGSHORE, P: LONGSHORE
|
Case Closed |
2021-03-24
|
Related Activity
Type |
Inspection |
Activity Nr |
1500661 |
Health |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19170112 A01 |
Issuance Date |
2021-02-05 |
Abatement Due Date |
2021-02-18 |
Current Penalty |
4962.0 |
Initial Penalty |
7461.0 |
Final Order |
2021-03-09 |
Nr Instances |
1 |
Nr Exposed |
45 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1917.112(a)(1): Vehicle curbs, bull rails, or other effective barriers at least 6 inches in height were not provided at the waterside edges of aprons and bulkheads.: a) Terminal 3 - On or about October 22, 2020, employees operated and parked powered industrial vehicles and motor vehicles at the waterside edge with no vehicle curb, bull rails, or other effective barriers provided, exposing employees to drowning hazards. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19170122 D |
Issuance Date |
2021-02-05 |
Abatement Due Date |
2021-02-18 |
Current Penalty |
3969.0 |
Initial Penalty |
5969.0 |
Final Order |
2021-03-09 |
Nr Instances |
1 |
Nr Exposed |
7 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1917.122(d):The minimum width of an employee exit was not 28 inches(71.12 cm).: a) Maintenance Shop - On or about October 22, 2020, employees entered the tool room to obtain tools for use, but the exit was not at least 28 inches in width to allow proper exit in the event of an emergency, exposing employees to fire hazards. |
|
Citation ID |
01003 |
Citaton Type |
Other |
Standard Cited |
19170151 B01 |
Issuance Date |
2021-02-05 |
Abatement Due Date |
2021-02-18 |
Current Penalty |
4178.0 |
Initial Penalty |
5969.0 |
Final Order |
2021-03-09 |
Nr Instances |
1 |
Nr Exposed |
7 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1917.151(b)(1): Danger zones on machines and equipment used by employees were not guarded. a) Maintenance Shop - On or about October 22, 2020, employees operated a Jet drill press, which was not guarded at the point of operation, exposing employees to caught-in hazards. |
|
|
345006613
|
1032100
|
2020-10-21
|
PIER 2 AND 3, KODIAK, AK, 99615
|
|
Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Health
|
Close Conference |
2020-10-22
|
Emphasis |
L: LONGSHORE, P: LONGSHORE
|
Case Closed |
2020-10-22
|
Related Activity
Type |
Inspection |
Activity Nr |
1499355 |
Safety |
Yes |
|
|
343207635
|
1032100
|
2018-06-06
|
1717 TIDEWATER ROAD PORT OF ANCHORAGE, ANCHORAGE, AK, 99501
|
|
Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Health
|
Close Conference |
2018-06-06
|
Emphasis |
L: LONGSHORE
|
Case Closed |
2018-09-14
|
Related Activity
Type |
Complaint |
Activity Nr |
1345033 |
Health |
Yes |
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Other |
Standard Cited |
19101001 J03 III |
Issuance Date |
2018-08-21 |
Current Penalty |
5543.0 |
Initial Penalty |
6929.0 |
Final Order |
2018-09-10 |
Nr Instances |
1 |
Nr Exposed |
1 |
Related Event Code (REC) |
Complaint |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1001(j)(3)(i): The employer did not exercise a due diligent attempt to inform employees and/or other employers about the presence or location of asbestos-containing material (ACM) and presumed asbestos-containing material (PACM): Administration Builiding, Room T107: On or about June 6, 2018 and at times prior thereto, the employer did not ensure the subcontractor was informed of presence, location, and quantity of mastic containing 5.0 to 18.0% asbestos prior to carpet removal. |
|
Citation ID |
01001B |
Citaton Type |
Other |
Standard Cited |
19101001 J04 I |
Issuance Date |
2018-08-21 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2018-09-10 |
Nr Instances |
1 |
Nr Exposed |
1 |
Related Event Code (REC) |
Complaint |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1001(j)(4)(i): The employer did not ensure labels or signs required by 29 CFR 1910.1001(j)(4)(i) for previously installed presumed asbestos-containing material (PACM) and/or other asbestos-containing material (ACM) were attached or posted in areas where they will be clearly notice by employees who are likely to be exposed: Administration Builiding, Room T107: On or about June 6, 2018 and at times prior thereto, when asbestos abatement was occurring, the door was not posted with the required signage and waste was not properly labeled. |
|
Citation ID |
01001C |
Citaton Type |
Other |
Standard Cited |
19101001 J07 IV |
Issuance Date |
2018-08-21 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2018-09-10 |
Nr Instances |
1 |
Nr Exposed |
1 |
Related Event Code (REC) |
Complaint |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1001(j)(7)(iv): The employer did not provide to all employees who perform housekeeping work in areas where ACM and/or PACM is present, an asbestos awareness training course covering the health effects of asbestos; and/or locations of ACM and/or recognition of ACM and PACM damage and deterioration and/or requirements in this standard related to housekeeping, and/or proper response to fiber release episodes: Administration Builiding, Room T107: On or about June 6, 2018 and at times prior thereto, employee(s) did not receive the asbestos awareness training. |
|
|
342947652
|
1032100
|
2018-02-09
|
DUTCH HARBOR TERMINAL, DUTCH HARBOR, AK, 99692
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2018-02-09
|
Emphasis |
L: LONGSHORE, P: LONGSHORE
|
Case Closed |
2018-07-16
|
Related Activity
Type |
Inspection |
Activity Nr |
1294758 |
Health |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Other |
Standard Cited |
5A0001 |
Issuance Date |
2018-03-22 |
Abatement Due Date |
2018-04-12 |
Current Penalty |
5654.0 |
Initial Penalty |
5654.0 |
Final Order |
2018-04-30 |
Nr Instances |
1 |
Nr Exposed |
3 |
FTA Current Penalty |
0.0 |
Citation text line |
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees: Matson Facility: On or about February 9, 2018 and at times prior thereto, employees operated Self-Propelled Articulating Boom Lift's in the terminal area utilizing a 6 foot deceleration lanyard for their fall protection. This condition exposed the employees to a fall hazard of approximately 5 -15 feet in the event of being ejected out of the lift. |
|
|
342947587
|
1032100
|
2018-02-09
|
DUTCH HARBOR TERMINAL, DUTCH HARBOR, AK, 99692
|
|
Inspection Type |
Planned |
Scope |
Complete |
Safety/Health |
Health |
Close Conference |
2018-02-09 |
Emphasis |
P: LONGSHORE, L: LONGSHORE |
Case Closed |
2018-07-16 |
Related Activity
Type |
Inspection |
Activity Nr |
1294765 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Other |
Standard Cited |
19170091 A01 |
Issuance Date |
2018-03-22 |
Abatement Due Date |
2018-04-12 |
Current Penalty |
7068.0 |
Initial Penalty |
7068.0 |
Final Order |
2018-04-30 |
Nr Instances |
1 |
Nr Exposed |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1917.91(a)(1): The employer did not ensure the use of eye and/or face protection equipment when employees were exposed to eye and/or face hazards: LTL Warehouse: On or about February 9, 2018 and at times prior thereto, employees were not using eye and face protection when operating high pressure washing equipment. This condition exposed the employees to eye injuries. |
|
Citation ID |
01002 |
Citaton Type |
Other |
Standard Cited |
19170154 |
Issuance Date |
2018-03-22 |
Current Penalty |
4240.0 |
Initial Penalty |
4240.0 |
Final Order |
2018-04-30 |
Nr Instances |
1 |
Nr Exposed |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1917.154: Compressed air was used to clean employees: Shop, Bay 3/4: On or about February 9, 2018 and at times prior thereto, compressed air rated at 140 p.s.i.g. was used by an employee to blow himself down prior to break. This condition exposed the employee to air embolism hazards from direct contact with the employees skin surface. |
|
|
342257284
|
1032100
|
2017-04-18
|
MARINE BUILDING 2010 ANCHORAGE PORT ROAD, ANCHORAGE, AK, 99501
|
|
Inspection Type |
Complaint |
Scope |
Partial |
Safety/Health |
Health |
Close Conference |
2017-04-20 |
Emphasis |
L: LONGSHORE |
Case Closed |
2017-06-06 |
Related Activity
Type |
Complaint |
Activity Nr |
1201676 |
Health |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Other |
Standard Cited |
19101001 J03 I |
Issuance Date |
2017-05-01 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2017-05-26 |
Nr Instances |
1 |
Nr Exposed |
35 |
Related Event Code (REC) |
Complaint |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1001(j)(3)(i): The employer did not determine the presence, location, and quantity of asbestos-containing material (ACM) and/or presumed asbestos-containing material (PACM) at the work site: 2010 Anchorage Port Road, Marine Building, Restrooms: On or about December 7, 2016 and at times prior thereto, during maintenance of the restroom facilities, ACM or PACM was not determined prior to the work activity. This condition disturbed ACM and potentially exposed employees to inhalation hazards. |
|
|
341346542
|
1032100
|
2016-03-23
|
1717 TIDEWATER ROAD PORT OF ANCHORAGE, ANCHORAGE, AK, 99501
|
|
Inspection Type |
Planned |
Scope |
Complete |
Safety/Health |
Health |
Close Conference |
2016-03-23 |
Emphasis |
L: LONGSHORE, P: LONGSHORE |
Case Closed |
2016-04-29 |
Related Activity
Type |
Inspection |
Activity Nr |
1134676 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Other |
Standard Cited |
19170151 G04 |
Issuance Date |
2016-04-01 |
Current Penalty |
2295.0 |
Initial Penalty |
2295.0 |
Final Order |
2016-04-15 |
Nr Instances |
1 |
Nr Exposed |
4 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1917.151(g)(4): Work rests on fixed grinding machines were not adjusted closely to the wheel with a maximum opening of 1/8-inch (3.18 mm) and securely clamped. Fabrication/Chassis Shop: On or about 23 March 2016 and times prior thereto, the 10 inch, 1 H/P, 1725 RPM, Serial Number 5204, Dayton Bench Grinder's work rest measured approximately 3/8" form the abrasive wheel. Work rest is secured with a nut and bolt application. This condition exposed employees to a struck by hazard. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19101200 F05 |
Issuance Date |
2016-04-01 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2016-04-15 |
Nr Instances |
1 |
Nr Exposed |
4 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(f)(5): The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged, or marked with the identity and appropriate hazard warnings regarding the chemicals contained therein Fabrication/Chassis Shop: On or about 23 March 2016 and times prior thereto,an unattended plastic bottle; containing an unknown chemical substance was not marked identifying the product and the hazard warnings associated with it. This condition exposed employees to chemical burns, poisoning, and skin dermatitis. |
|
|
341346765
|
1032100
|
2016-03-23
|
1717 TIDEWATER ROAD PORT OF ANCHORAGE, ANCHORAGE, AK, 99501
|
|
Inspection Type |
Planned |
Scope |
Complete |
Safety/Health |
Safety |
Close Conference |
2016-03-23 |
Emphasis |
L: LONGSHORE, P: LONGSHORE |
Case Closed |
2016-04-29 |
Related Activity
Type |
Inspection |
Activity Nr |
1134654 |
Health |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100305 B01 II |
Issuance Date |
2016-04-01 |
Abatement Due Date |
2016-04-29 |
Current Penalty |
1606.5 |
Initial Penalty |
2295.0 |
Final Order |
2016-04-15 |
Nr Instances |
4 |
Nr Exposed |
21 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed. Main Maintenance and Chassis Shops; on or about 23 March 2016 and times prior thereto; four instances were noted where energized electrical openings were not effectively closed: a. Bay 16 west wall; adjacent to roll-up door; an energized electrical wall outlet was missing a knockout plug on the right hand side. b. Old battery storage area; an energized electrical box was missing a knockout plug on the top of the electrical box. c. Parts room, outlet labeled PNL 1A CKT 17; an energized electrical wall outlet was missing a knockout plug on the right hand side. d. Chassis Shop electrical panel C; an energized 220 volt electrical panel was not fitted with the correct size blank cover on breaker labeled number 22. This condition exposed employees to electrical shock and electrical burn hazards. |
|
Citation ID |
01002 |
Citaton Type |
Other |
Standard Cited |
19100334 A02 I |
Issuance Date |
2016-04-01 |
Abatement Due Date |
2016-04-29 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2016-04-15 |
Nr Instances |
3 |
Nr Exposed |
21 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.334(a)(2)(i): Portable cord and plug connected equipment and flexible cord sets (extension cords) were not visually inspected before use on any shift for external defects (such as loose parts, deformed and missing pins, or damage to outer jacket or insulation) and for evidence of possible internal damage (such as pinched or crushed outer jacket). Main Maintenance Shop; on or about 23 March 2016 and times prior thereto; three instances were noted where electrical cords were damaged: a. Bays 6 and 7; a portable light stand had damaged to the outer insulation where the electrical cord and plug attach exposing wires. b. Wash Bay; a 50 foot blue extension cord had damaged to the outer insulation where the cord and plug attach exposing wires. c. Bay 9; the electrical cord on the oil filter crusher had damage to the outer insulation where the cord and plug was damaged. This condition exposed employees to electrical shock and electrical burn hazards. |
|
|