347554446
|
1050210
|
2024-06-07
|
CENTRAL COMPRESSOR PLANT 70.32091988597153, -148.50543843325107, PRUDHOE BAY, AK, 99734
|
|
Inspection Type |
Unprog Rel
|
Scope |
Partial
|
Safety/Health |
Health
|
Close Conference |
2024-11-12
|
Case Closed |
2024-11-25
|
|
347774234
|
1050210
|
2024-06-07
|
CENTRAL COMPRESSOR PLANT, PRUDHOE BAY, AK, 99734
|
|
Inspection Type |
Unprog Rel
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2024-11-12
|
|
347502031
|
1050210
|
2024-05-20
|
MILNE POINT, PRUDHOE BAY, AK, 99734
|
|
Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2024-08-14
|
Case Closed |
2024-09-18
|
|
346810740
|
1032100
|
2023-07-04
|
NORTH STAR ISLAND, PRUDHOE BAY, AK, 99734
|
|
Inspection Type |
Unprog Rel
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2023-07-04
|
Case Closed |
2024-02-06
|
|
346658107
|
1050210
|
2023-04-21
|
CHOSEN SHOP YARD, PRUDHOE BAY, AK, 99734
|
|
Inspection Type |
Unprog Rel
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2023-09-13
|
|
346089956
|
1032100
|
2022-07-13
|
ENDICOTT ISLAND MPI, PRUDHOE BAY, AK, 99734
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Health
|
Close Conference |
2022-07-14
|
Case Closed |
2023-02-24
|
|
346078892
|
1032100
|
2022-07-13
|
ENDICOTT ISLAND MPI, PRUDHOE BAY, AK, 99734
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2022-07-14
|
Case Closed |
2023-08-15
|
|
345679203
|
1050210
|
2021-12-09
|
6160 CARL BRADY DR, ANCHORAGE, AK, 99502
|
|
Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2022-01-14
|
Case Closed |
2022-04-13
|
|
345137582
|
1032100
|
2021-02-04
|
GRAYLING PLATFORM, NIKISKI, AK, 99635
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2021-02-05
|
Emphasis |
L: PLATFORM, P: PLATFORM
|
Case Closed |
2021-07-12
|
Related Activity
Type |
Inspection |
Activity Nr |
1513809 |
Health |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100028 B01 I |
Issuance Date |
2021-06-09 |
Abatement Due Date |
2021-06-21 |
Current Penalty |
5106.0 |
Initial Penalty |
7295.0 |
Final Order |
2021-07-07 |
Nr Instances |
1 |
Nr Exposed |
9 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.28(b)(1)(i): Except as provided elsewhere in this section 29 CFR 1910.28, the employer did not ensure that each employee on a walking-working surface with an unprotected side or edge that is 4 feet (1.2 m) or more above a lower level is protected from falling by one or more of the systems described in 29 CFR 1910.28(b)(1)(i): a) Wellhead 4 Hallway: On or about February 4, 2021, employees accessed a valve landing at a height of eight (8) feet from grade below without the use of fall protection, exposing employees to fall hazards. |
|
Citation ID |
01002 |
Citaton Type |
Other |
Standard Cited |
19100303 G01 II |
Issuance Date |
2021-06-09 |
Current Penalty |
5741.0 |
Initial Penalty |
5471.0 |
Final Order |
2021-07-07 |
Nr Instances |
1 |
Nr Exposed |
9 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.303(g)(1)(ii):The required working space about electric equipment rated 600 volts, nominal, or less to ground, was used for storage: a) Booster Packet Area: On or about February 4, 2021, air conditioning units, a metal skylight fixture, and wood were stored at the main control area, exposing employees to electrical and fire hazards. |
|
|
345137566
|
1032100
|
2021-02-04
|
C PLATFORM, NIKISKI, AK, 99635
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2021-02-05
|
Emphasis |
L: PLATFORM, P: PLATFORM
|
Case Closed |
2021-07-12
|
Related Activity
Type |
Inspection |
Activity Nr |
1513807 |
Health |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Other |
Standard Cited |
19100022 A03 |
Issuance Date |
2021-06-09 |
Abatement Due Date |
2021-06-21 |
Current Penalty |
5741.0 |
Initial Penalty |
5471.0 |
Final Order |
2021-07-07 |
Nr Instances |
1 |
Nr Exposed |
10 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.22(a)(3): The employer did not ensure that walking-working surfaces are maintained free of hazards such as sharp or protruding objects, loose boards, corrosion, leaks, spills, snow, and ice. a) Electric Shop: On or about February 4, 2021, two hatch doors protruded 1 1/2 inches from the walking-working surface, exposing employees to tripping hazards. b) Sewer Plant: On or about February 4, 2021, a hatch door protruded 1 1/2 inches from the walking-working surface, exposing employees to tripping hazards. |
|
|
345137426
|
1032100
|
2021-02-03
|
DOLLY VARDEN PLATFORM, NIKISKI, AK, 99635
|
|
Inspection Type |
Planned |
Scope |
Complete |
Safety/Health |
Safety |
Close Conference |
2021-02-05 |
Emphasis |
L: PLATFORM, P: PLATFORM |
Case Closed |
2021-07-12 |
Related Activity
Type |
Inspection |
Activity Nr |
1513802 |
Health |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100028 B01 I |
Issuance Date |
2021-06-09 |
Current Penalty |
6383.0 |
Initial Penalty |
9119.0 |
Final Order |
2021-07-07 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.28(b)(1)(i): Except as provided elsewhere in this section 29 CFR 1910.28, the employer did not ensure that each employee on a walking-working surface with an unprotected side or edge that is 4 feet (1.2 m) or more above a lower level is protected from falling by one or more of the systems described in 29 CFR 1910.28(b)(1)(i): a) Separator Room: On or about February 3, 2021, employees performed response operations to isolate a valve between separators two (2) and three (3), working on a walking-working platform with unprotected sides and edges at a height of nine (9) feet and six (6) inches, exposing employees to fall hazards. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100212 A01 |
Issuance Date |
2021-06-09 |
Abatement Due Date |
2021-06-21 |
Current Penalty |
5106.0 |
Initial Penalty |
7295.0 |
Final Order |
2021-07-07 |
Nr Instances |
3 |
Nr Exposed |
6 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.212(a)(1):One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a) Welding Area: On or about February 3, 2021, employees operated a Dayton 20 inch drill press for parts repair unguarded at the point of operation, exposing employees to caught-in and amputation hazards. b) Maintenance Shop: On or about February 3, 2021, employees operated a Delta drill press, model 70-200 for parts repair unguarded at the point of operation, exposing employees to caught-in and amputation hazards. c) Mechanic Shop: On or about February 3, 2021, employees operated a Dayton mill drill, model 2AC40B for parts repair unguarded at the point of operation, exposing employees to caught-in and amputation hazards. |
|
Citation ID |
01003 |
Citaton Type |
Other |
Standard Cited |
19100303 G01 II |
Issuance Date |
2021-06-09 |
Current Penalty |
4650.0 |
Initial Penalty |
4650.0 |
Final Order |
2021-07-07 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.303(g)(1)(ii):The required working space about electric equipment rated 600 volts, nominal, or less to ground, was used for storage: a) I & E Room: On or about February 3, 2021, employees performed maintenance and repair of low-voltage equipment, but the main control panel area was stored with computers, PLC's, actuators, cardboard boxes, and wood, exposing employees to electrical and fire hazards. |
|
|
345137475
|
1032100
|
2021-02-03
|
A PLATFORM, NIKISKI, AK, 99635
|
|
Inspection Type |
Planned |
Scope |
Complete |
Safety/Health |
Safety |
Close Conference |
2021-02-05 |
Emphasis |
L: PLATFORM, P: PLATFORM |
Case Closed |
2021-07-12 |
Related Activity
Type |
Inspection |
Activity Nr |
1513805 |
Health |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Other |
Standard Cited |
19100219 C02 I |
Issuance Date |
2021-06-09 |
Current Penalty |
6201.0 |
Initial Penalty |
6201.0 |
Final Order |
2021-07-07 |
Nr Instances |
1 |
Nr Exposed |
10 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.219(c)(2)(i): All exposed part(s) of horizontal shafting seven (7) feet or less from floor or working platform were not protected by stationary casing(s) enclosing shafting completely or by trough(s) enclosing sides and top or sides and bottom of shafting: a) Bay 3: On or about February 3, 2021, employees lubricated and inspected poly pumps, an exposed horizontal rotating shaft for poly pump 2 was not guarded and located less than seven (7) feet from the floor, exposing employees to caught in and amputation hazards. |
|
Citation ID |
01002 |
Citaton Type |
Other |
Standard Cited |
19100303 G01 II |
Issuance Date |
2021-06-09 |
Current Penalty |
4650.0 |
Initial Penalty |
4650.0 |
Final Order |
2021-07-07 |
Nr Instances |
1 |
Nr Exposed |
6 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.303(g)(1)(ii): The required working space about electric equipment rated 600 volts, nominal, or less to ground, was used for storage: a) Storage Room: On or about February 3, 2021, pipe fittings were stored in the main control panel area, exposing employees to electrical and fire hazards. |
|
|
345138028
|
1032100
|
2021-02-03
|
PLATFORM DOLLY VARDEN, NIKISKI, AK, 99635
|
|
Inspection Type |
Planned |
Scope |
Complete |
Safety/Health |
Health |
Close Conference |
2021-02-05 |
Emphasis |
L: PLATFORM, P: PLATFORM |
Case Closed |
2021-09-07 |
Related Activity
Type |
Inspection |
Activity Nr |
1514890 |
Health |
Yes |
|
Type |
Inspection |
Activity Nr |
1513742 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1514878 |
Health |
Yes |
|
Type |
Inspection |
Activity Nr |
1514886 |
Health |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Other |
Standard Cited |
19101200 F06 II |
Issuance Date |
2021-07-30 |
Current Penalty |
3481.0 |
Initial Penalty |
4973.0 |
Final Order |
2021-08-23 |
Nr Instances |
2 |
Nr Exposed |
13 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(f)(6)(ii): Except as provided in 29 CFR 1910.1200(f)(7) and 29 CFR 1910.1200(f)(8), the employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the product identifier and words, pictures, symbols, or combination thereof, which provide at least general information regarding the hazards of the chemicals and which, in conjunction with the other information immediately available to employees under the hazard communication program, would provide employees with the specific information regarding the physical and health hazards of the hazardous chemical. a) Electrical Room: On or about February 2, 2021 an unlabeled container with unknown content was placed on top of a tool cabinet bench potentially exposing employees to chemical hazards. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19100095 D01 II |
Issuance Date |
2021-07-30 |
Abatement Due Date |
2021-08-25 |
Current Penalty |
0.0 |
Initial Penalty |
931.0 |
Final Order |
2021-08-23 |
Nr Instances |
1 |
Nr Exposed |
13 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.95(d)(1)(ii): Unless the employer can show that area sampling produces equivalent exposure monitoring, the employer did not use representative personal sampling to comply with the monitoring requirements of 29 CFR 1910.95(d): a) Dolly Varden Platform: On or about February 3, 2021 an employee was exposed to high noise levels at locations identified in a noise survey performed by a third party company in year 2008. A noise hazard assessment by use of representative personal sampling methods was not determined for noise exposure levels as comparison to OSHA's TWA Action Level of 85 dBA for 8 hours and did not estimate for a 12-hour extended work shift. |
|
|
343651782
|
1050210
|
2018-12-07
|
1000 MILNE POINT, PRUDHOE BAY, AK, 99734
|
|
Inspection Type |
Unprog Rel |
Scope |
Partial |
Safety/Health |
Safety |
Close Conference |
2019-04-09 |
Case Closed |
2019-09-25 |
Related Activity
Type |
Inspection |
Activity Nr |
1364879 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100181 I04 II |
Issuance Date |
2019-04-25 |
Abatement Due Date |
2019-05-21 |
Current Penalty |
12934.0 |
Initial Penalty |
12934.0 |
Final Order |
2019-04-29 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19101030 D04 II A |
Issuance Date |
2019-04-25 |
Abatement Due Date |
2019-05-21 |
Current Penalty |
12934.0 |
Initial Penalty |
12934.0 |
Final Order |
2019-04-29 |
Nr Instances |
1 |
Nr Exposed |
515 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
|
|
343133716
|
1032100
|
2018-05-02
|
STEELHEAD PLATFORM COOK INLET, NIKISKI, AK, 99635
|
|
Inspection Type |
Planned |
Scope |
Complete |
Safety/Health |
Safety |
Close Conference |
2018-05-02 |
Emphasis |
L: PLATFORM, P: PLATFORM |
Case Closed |
2018-06-08 |
Related Activity
Type |
Inspection |
Activity Nr |
1314641 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1314927 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1314685 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1314695 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Other |
Standard Cited |
19100151 C |
Issuance Date |
2018-05-10 |
Abatement Due Date |
2018-06-08 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2018-06-08 |
Nr Instances |
1 |
Nr Exposed |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use: Steelhead Platform, Oil Shipping Pump Room: On or about 02 May 2018 and times prior thereto; the emergency eyes wash station was drained. This condition exposed employees to eye trauma hazards. |
|
Citation ID |
01002 |
Citaton Type |
Other |
Standard Cited |
19101200 F05 |
Issuance Date |
2018-05-10 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2018-06-08 |
Nr Instances |
1 |
Nr Exposed |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(f)(5): The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged, or marked with the identity and appropriate hazard warnings regarding the chemicals contained therein: Steelhead oil Platform, Instrument Shop: On or about 02 May 2018 and times prior thereto, unattended plastic bottle; containing an unknown chemical substance was not marked identifying the product and the hazard warnings associated with it. This condition exposed employees to chemical burns, poisoning, and skin dermatitis. |
|
|
343133369
|
1032100
|
2018-05-01
|
KING SALMON PLATFORM COOK INLET, NIKISKI, AK, 99635
|
|
Inspection Type |
Planned |
Scope |
Complete |
Safety/Health |
Safety |
Close Conference |
2018-05-02 |
Emphasis |
L: PLATFORM, P: PLATFORM |
Case Closed |
2019-01-29 |
Related Activity
Type |
Inspection |
Activity Nr |
1314673 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1314593 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100212 B |
Issuance Date |
2018-05-10 |
Abatement Due Date |
2018-06-08 |
Current Penalty |
3770.0 |
Initial Penalty |
4712.0 |
Final Order |
2018-12-11 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.212(b): Machine(s) designed for fixed location(s) were not securely anchored to prevent walking or moving: King Salmon Platform, Maintenance Shop: On or about 01 May 2018 and times prior thereto, the Jet Floor Standing Drill Press, Model # JDP-20MF was not was not secured to a fixed location. This condition exposed employees to a struck by hazard. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19100305 G02 III |
Issuance Date |
2018-05-10 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2018-12-11 |
Nr Instances |
1 |
Nr Exposed |
2 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws: King Salmon Platform, Drive Room: On or about 01 May 2018and times prior thereto, a 30 foot yellow extension cord exhibited strain relief. This condition exposed employees to an electrical shock and burn hazard. |
|
|
342232477
|
1032100
|
2017-03-20
|
NORTHSTAR ISLAND, PRUDHOE BAY, AK, 99734
|
|
Inspection Type |
Planned |
Scope |
Complete |
Safety/Health |
Safety |
Close Conference |
2017-04-05 |
Emphasis |
L: PLATFORM, P: PLATFORM |
Case Closed |
2017-05-23 |
Related Activity
Type |
Inspection |
Activity Nr |
1223237 |
Health |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100212 A01 |
Issuance Date |
2017-04-19 |
Abatement Due Date |
2017-05-17 |
Current Penalty |
3500.0 |
Initial Penalty |
4617.0 |
Final Order |
2017-05-12 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks Maintenance Shop: On or about 20 March 2017 and times prior thereto, the Bridgeport Milling Machine, S/N HJ319804 was missing the point of operation guard. This condition exposed employees to a caught/struck by hazard. |
|
|
342232378
|
1032100
|
2017-03-20
|
NORTHSTAR ISLAND, PRUDHOE BAY, AK, 99734
|
|
Inspection Type |
Planned |
Scope |
Complete |
Safety/Health |
Health |
Close Conference |
2017-04-05 |
Emphasis |
L: PLATFORM, P: PLATFORM |
Case Closed |
2017-05-12 |
Related Activity
Type |
Inspection |
Activity Nr |
1224087 |
Health |
Yes |
|
Type |
Inspection |
Activity Nr |
1223355 |
Health |
Yes |
|
Type |
Inspection |
Activity Nr |
1223364 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1223247 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1223345 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19101020 D01 II |
Issuance Date |
2017-04-19 |
Abatement Due Date |
2017-05-17 |
Current Penalty |
0.0 |
Initial Penalty |
4617.0 |
Final Order |
2017-05-12 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1020(d)(1)(ii): Each employee exposure record was not preserved and maintained for at least thirty years: South Process Area and Adjacent: On or about April 4, 2017 and at times prior thereto, employee exposure records did not reflect exposures of employees required to perform semi-annual shutter and three year leak test surveys on level controllers of the LP Flare Scrubber and NGL Separator. This condition underestimated employee exposure to ionizing radiation sources. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19100151 C |
Issuance Date |
2017-04-19 |
Abatement Due Date |
2017-05-17 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2017-05-12 |
Nr Instances |
1 |
Nr Exposed |
6 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use: TG Regeneration Skid: On or about April 4, 2017 and at times prior thereto, during the process of adding an 85% Triethanolamine solution to balance the ph of the process, the placement of the facility for flushing the eyes was not provided in the work area in accordance with the standard. This condition exposed employees to eye irritation hazards. |
|
|
341147940
|
1050210
|
2015-12-30
|
ASR1 MILNE POINT, PRUDHOE BAY, AK, 99734
|
|
Inspection Type |
Referral |
Scope |
Records |
Safety/Health |
Health |
Close Conference |
2016-03-21 |
Case Closed |
2016-05-04 |
Related Activity
Type |
Referral |
Activity Nr |
1049988 |
Health |
Yes |
|
Type |
Inspection |
Activity Nr |
1128556 |
Health |
Yes |
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Other |
Standard Cited |
19100120 Q06 I A |
Issuance Date |
2016-03-22 |
Abatement Due Date |
2016-05-09 |
Current Penalty |
0.0 |
Initial Penalty |
5000.0 |
Final Order |
2016-05-04 |
Nr Instances |
3 |
Nr Exposed |
3 |
Related Event Code (REC) |
Referral |
FTA Current Penalty |
0.0 |
|
Citation ID |
01001B |
Citaton Type |
Other |
Standard Cited |
19100120 Q06 I C |
Issuance Date |
2016-03-22 |
Abatement Due Date |
2016-05-09 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2016-05-04 |
Nr Instances |
3 |
Nr Exposed |
3 |
Related Event Code (REC) |
Referral |
FTA Current Penalty |
0.0 |
|
Citation ID |
01002 |
Citaton Type |
Other |
Standard Cited |
19100132 D01 I |
Issuance Date |
2016-03-22 |
Abatement Due Date |
2016-05-09 |
Current Penalty |
0.0 |
Initial Penalty |
5000.0 |
Final Order |
2016-05-04 |
Nr Instances |
1 |
Nr Exposed |
3 |
Related Event Code (REC) |
Referral |
FTA Current Penalty |
0.0 |
|
|
340819358
|
1032100
|
2015-07-27
|
ENDICOTT ISLAND MPI, PRUDHOE BAY, AK, 99734
|
|
Inspection Type |
Planned |
Scope |
Complete |
Safety/Health |
Health |
Close Conference |
2015-07-29 |
Emphasis |
L: PLATFORM, P: PLATFORM |
Case Closed |
2015-09-30 |
Related Activity
Type |
Inspection |
Activity Nr |
1081956 |
Health |
Yes |
|
Type |
Inspection |
Activity Nr |
1082184 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1081962 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1082231 |
Health |
Yes |
|
Type |
Inspection |
Activity Nr |
1082202 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19100023 C01 |
Issuance Date |
2015-08-25 |
Abatement Due Date |
2015-09-23 |
Current Penalty |
1275.0 |
Initial Penalty |
2550.0 |
Final Order |
2015-09-18 |
Nr Instances |
2 |
Nr Exposed |
2 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.23(c)(1): Open-sided floors and/or platforms four feet or more above adjacent floor or ground level were not guarded with standard railings (or equivalent) and toeboards: (a) Generator 4505: On or about July 28, 2015 and at times prior thereto, the access platform for the generator was not guarded with a standard railing or equivalent. This condition exposed employees to a fall hazard of four and one-half (4 feet, 6 inches) above the concrete floor level. (b) Generator 4506: On or about July 28, 2015 and at times prior thereto, the access platform for the generator was not guarded with a standard railing or equivalent. This condition exposed employees to a fall hazard of four and one-half (4 feet, 6 inches) above the concrete floor level. Note: Toeboards are only required when persons can pass, there is moving equipment or there is equipment with which falling materials could create a hazard. |
|
Citation ID |
01001B |
Citaton Type |
Other |
Standard Cited |
19100023 A08 |
Issuance Date |
2015-08-25 |
Abatement Due Date |
2015-09-23 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2015-09-18 |
Nr Instances |
1 |
Nr Exposed |
4 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.23(a)(8): Every floor hole into which persons can accidentally walk were not guarded: Wellheads: On or about July 27, 2015 and at times prior thereto, the platform surrounding wellhead 2-20 and similar wellheads exposed walk-in hazards measuring 44 X 41 X 12 inches as an example. This condition exposed employees to step-in hazards. |
|
Citation ID |
01002 |
Citaton Type |
Other |
Standard Cited |
19100242 B |
Issuance Date |
2015-08-25 |
Abatement Due Date |
2015-09-23 |
Current Penalty |
4250.0 |
Initial Penalty |
4250.0 |
Final Order |
2015-09-18 |
Nr Instances |
5 |
Nr Exposed |
6 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.: (a) Machine Shop: On or about July 28, 2015 and at times prior thereto, compressed air for cleaning exceeded 100 p.s.i.g.. This condition exposed employees to air embolism hazards when the air nozzle is dead-ended to the skin. (b) Fabrication Shop: On or about July 28, 2015 and at times prior thereto, compressed air for cleaning exceeded 100 p.s.i.g.. This condition exposed employees to air embolism hazards when the air nozzle is dead-ended to the skin. (c) Carpentry Shop: On or about July 28, 2015 and at times prior thereto, compressed air for cleaning exceeded 100 p.s.i.g.. This condition exposed employees to air embolism hazards when the air nozzle is dead-ended to the skin. (d) Environmental Shop: On or about July 28, 2015 and at times prior thereto, compressed air for cleaning exceeded 100 p.s.i.g.. This condition exposed employees to air embolism hazards when the air nozzle is dead-ended to the skin. (e) Vehicle Maintenance Shop: On or about July 28, 2015 and at times prior thereto, compressed air for cleaning exceeded 100 p.s.i.g.. This condition exposed employees to air embolism hazards when the air nozzle is dead-ended to the skin. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19100022 D01 |
Issuance Date |
2015-08-25 |
Abatement Due Date |
2015-09-23 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2015-09-18 |
Nr Instances |
1 |
Nr Exposed |
4 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.22(d)(1): On every building or other structure, or part thereof, used for mercantile, business, industrial or storage purposes, the loads approved by the building official were not marked on plates of approved design and securely affixed in a conspicuous place in each space to which they relate. Warehouse: On or about July 28, 2015 and at times prior thereto, a load limit value was not marked on the overhead storage. This condition limited employee information on ensuring storage structure could adequately support uniform loads. |
|
Citation ID |
02002 |
Citaton Type |
Other |
Standard Cited |
19100101 A |
Issuance Date |
2015-08-25 |
Abatement Due Date |
2015-09-23 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2015-09-18 |
Nr Instances |
2 |
Nr Exposed |
4 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.101(a): The employer did not determine that compressed gas cylinders under his control were in a safe condition to the extent that can be determined by visual or other inspections conducted as prescribed in the Hazardous Materials Regulations: POL Warehouse: On or about July 28, 2015 and at times prior, two (2) compressed gas cylinders marked as containing R-12 refrigerant gas were noticeably pitted, dented, and certification(s) were illegible. This condition limited the employer's ability to ensure cylinders were safe for use and transport. |
|
|
340819622
|
1032100
|
2015-07-27
|
ENDICOTT ISLAND MPI, PRUDHOE BAY, AK, 99734
|
|
Inspection Type |
Planned |
Scope |
Complete |
Safety/Health |
Safety |
Close Conference |
2015-07-27 |
Emphasis |
L: PLATFORM, P: PLATFORM |
Case Closed |
2015-09-30 |
Related Activity
Type |
Inspection |
Activity Nr |
1081963 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1082009 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1082014 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1081935 |
Health |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100219 D01 |
Issuance Date |
2015-08-25 |
Current Penalty |
1084.0 |
Initial Penalty |
2168.0 |
Final Order |
2015-09-17 |
Nr Instances |
2 |
Nr Exposed |
2 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o): Endicott MPI, Sewage Treatment Plant: On or about 28 July 2015 and times prior thereto, two Effluent sewage pump pulleys had an opening measuring approximately 8 inches by 8 inches. This condition exposed employees to a caught in hazard. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19100303 F02 |
Issuance Date |
2015-08-25 |
Abatement Due Date |
2015-09-16 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2015-09-17 |
Nr Instances |
1 |
Nr Exposed |
2 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident. Endicott Island, MOC, Carpenter Room: On or about 28 July 2015 and times prior thereto, electrical panel PAP-E3-4539 was not properly identified with a listing for the circuits. This condition exposed employees to an electrical shock and burn hazard. |
|
Citation ID |
02002 |
Citaton Type |
Other |
Standard Cited |
19100305 G01 IV A |
Issuance Date |
2015-08-25 |
Abatement Due Date |
2015-09-23 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2015-09-17 |
Nr Instances |
1 |
Nr Exposed |
2 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure Endicott MPI, Water Plant: On or about 28 July 2015 and times prior thereto, a 50 foot polar/Solar 12-3 extension cord was routed and connected to stanchion to operate the corrosion inhibitor pump. This condition exposed employees to an electrical shock and burn hazard. |
|
|
339085243
|
1032100
|
2013-05-21
|
MONOPOD PLATFORM, NIKISKI, AK, 99635
|
|
Inspection Type |
Planned |
Scope |
Complete |
Safety/Health |
Safety |
Close Conference |
2013-05-21 |
Emphasis |
L: PLATFORM, P: PLATFORM |
Case Closed |
2013-06-25 |
Violation Items
Citation ID |
01001 |
Citaton Type |
Other |
Standard Cited |
19100147 C05 II D |
Issuance Date |
2013-06-05 |
Abatement Due Date |
2013-06-05 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Nr Instances |
1 |
Nr Exposed |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.147(c)(5)(ii)(D): Lockout devices and tagout devices did not indicate the identity of the employee applying the device(s). Monopod Platform, motor room; on or about 21 May 2013 and times prior thereto, the employer did not ensure that lock-out tag-out program provided the identity of the individual that applied the tag. The Notice tag located in the motor room for the air compressor # 3; was not marked identifying the individual that applied the tag. This condition exposed employees to inadvertent start-up of the equipment resulting in caught-in hazards. |
|
|
339082620
|
1032100
|
2013-05-20
|
ANNA PLATFORM, NIKISKI, AK, 99635
|
|
Inspection Type |
Planned |
Scope |
Complete |
Safety/Health |
Safety |
Close Conference |
2013-05-20 |
Emphasis |
L: PLATFORM, P: PLATFORM |
Case Closed |
2013-06-25 |
Related Activity
Type |
Inspection |
Activity Nr |
908608 |
Health |
Yes |
|
Type |
Inspection |
Activity Nr |
908525 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
908581 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
908553 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
908745 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
908738 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Other |
Standard Cited |
19100303 F02 |
Issuance Date |
2013-06-05 |
Abatement Due Date |
2013-06-19 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Nr Instances |
2 |
Nr Exposed |
4 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident: (a) Sewage Plant: On or about May 20, 2013 and at times prior thereto, the Square D service disconnect for the OmniPure system was not legibly marked. This condition exposed employees to electrical shock and inadvertent start-up when servicing the downstream equipment. (b) Laundry/Compressor Room: On or about May 20, 2013 and at times prior thereto, the Eaton/cutler-Hammer disconnect for the Jefferson Electric 240-480 volt transformer was not legibly marked. This condition exposed employees to electrical shock when servicing the downstream equipment. |
|
|
335226221
|
1032100
|
2012-07-12
|
STEELHEAD PLATFORM, NIKISKI, AK, 99635
|
|
Inspection Type |
Planned |
Scope |
Complete |
Safety/Health |
Safety |
Close Conference |
2012-07-12 |
Emphasis |
L: PLATFORM |
Case Closed |
2012-10-16 |
Related Activity
Type |
Inspection |
Activity Nr |
522620 |
Health |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Other |
Standard Cited |
19100022 A01 |
Issuance Date |
2012-09-07 |
Current Penalty |
2295.0 |
Initial Penalty |
2295.0 |
Final Order |
2012-09-28 |
Nr Instances |
1 |
Nr Exposed |
50 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.22(a)(1): All places of employment, passageways, storerooms or service rooms were not kept clean and orderly or in a sanitary condition. Steelhead Platform, Oil Test Separator Room: On or about 12 July 2012 and times prior thereto, The supply system lines going to the Turbine Engine Oil container had evidence of oil leakage into the aisle way in front of the container. Oil spill measured at approximately 36 inches in the aisle way. This condition exposed employees to slipping and fall hazards when working or transiting through the Oil Separator Test Room. |
|
|
335226205
|
1032100
|
2012-07-12
|
STEELHEAD PLATFORM, NIKISKI, AK, 99635
|
|
Inspection Type |
Planned |
Scope |
Complete |
Safety/Health |
Health |
Close Conference |
2012-07-12 |
Emphasis |
L: PLATFORM |
Case Closed |
2012-10-16 |
Related Activity
Type |
Inspection |
Activity Nr |
522622 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Other |
Standard Cited |
19100254 D09 III |
Issuance Date |
2012-09-07 |
Current Penalty |
2295.0 |
Initial Penalty |
2295.0 |
Final Order |
2012-09-28 |
Nr Instances |
1 |
Nr Exposed |
2 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.254(d)(9)(iii): Cables with damaged insulation or exposed bare conductors were not replaced: Dry Sack room: On or about July 12, 2012 and times prior thereto, the welding stinger was cut to the conductor at 24 inches from the holder. This exposed employees to electric shock hazards from coming in contact with the conductor during welding operations. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19100037 A04 |
Issuance Date |
2012-09-07 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Nr Instances |
1 |
Nr Exposed |
50 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.37(a)(4): Safeguards designed to protect employees during an emergency (e.g., sprinkler systems, alarm systems, fire doors, exit lighting) must be in proper working order at all times. 2nd floor living area: On or about July 12, 2012 and times prior thereto, both exit signs lights for both exit access areas were not working. This exposed employees to smoke inhalation hazards from delays in exiting the area. Dry Sack Room: On or about 12 July 2012 and times prior thereto, the emergency lighting in the Dry Sack Room was inoperable. This exposed employees to smoke inhalation and/or fire hazards from delays in exiting the building. |
|
Citation ID |
02002 |
Citaton Type |
Other |
Standard Cited |
19100242 A |
Issuance Date |
2012-09-07 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Nr Instances |
1 |
Nr Exposed |
2 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.242(a): Hand and portable powered tools or equipment were not kept in safe condition: Dry Sack room: On or about July 12, 2012 and times prior thereto, the Dewalt chop saw S/N 347579 had a damaged cord. This exposed employees to electric shock hazards. |
|
Citation ID |
02003 |
Citaton Type |
Other |
Standard Cited |
19100334 A03 II |
Issuance Date |
2012-09-07 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Nr Instances |
1 |
Nr Exposed |
2 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.334(a)(3)(ii): Attachment plugs and receptacles were connected or altered in a manner which prevented proper continuity of the electric equipment grounding conductor at the point where plugs were attached to receptacles: Dry Sack room: On or about July 12, 2012 and times prior thereto, an extension cord used for powering other equipment had no ground pin. This exposed employees to electrical shock hazards. |
|
|