342943651
|
1032100
|
2018-02-05
|
F/V ALASKA MIST COASTAL DOCK, DUTCH HARBOR, AK, 99692
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2018-02-05
|
Emphasis |
L: FISH, P: FISH
|
Case Closed |
2018-04-17
|
Related Activity
Type |
Inspection |
Activity Nr |
1294374 |
Health |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19150134 B |
Issuance Date |
2018-03-13 |
Abatement Due Date |
2018-04-10 |
Current Penalty |
1885.0 |
Initial Penalty |
1885.0 |
Final Order |
2018-04-10 |
Nr Instances |
2 |
Nr Exposed |
2 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1915.134(b): Work rests were not kept a distance not to exceed 1/8 inch from the surface of the wheel. F/V Alaska Mist, Coastal Dock, Engine Room; on or about 05 February 2018 and times prior thereto, two instances were noted where the work rest on bench grinders were not properly adjusted to a maximum of one-eighth of an inch from the abrasive wheel. a. Electrical room, a Dayton 8-inch bench grinder, model not legible, serial number 604477XJ94B had the tool rest adjusted to greater than 1/8 inch from the abrasive wheel. Distance was 1/4 inch from the abrasive wheel. b. Gear room, a Dayton 8-inch bench grinder, model not legible, serial number not legible; had the tool rest adjusted to greater than 1/8 inch from the abrasive wheel. Distance was 1/4 inch from the abrasive wheel. This condition exposed employees to a caught in hazard. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19150089 Q01 |
Issuance Date |
2018-03-13 |
Abatement Due Date |
2018-04-10 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2018-04-10 |
Nr Instances |
1 |
Nr Exposed |
2 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1915.89(q)(1): The employer did not conduct an audit of the lockout/tags-plus program and procedures currently in use at least annually to ensure that the procedures and the requirements of this section were being followed and to correct any deficiencies. F/V Alaska Mist, Coastal Dock, Engine Room; on or about 05 February 2018 and times prior thereto, the employer did not ensure that the annual audit of the lockout/tagout plus program was completed. This condition exposed employees to unsafe work practices. |
|
|
342943743
|
1032100
|
2018-02-05
|
F/V ALASKA MIST COASTAL DOCK, DUTCH HARBOR, AK, 99692
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Health
|
Close Conference |
2018-02-05
|
Emphasis |
L: FISH, P: FISH
|
Case Closed |
2018-04-17
|
Related Activity
Type |
Inspection |
Activity Nr |
1294365 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100134 H02 I |
Issuance Date |
2018-03-13 |
Abatement Due Date |
2018-04-10 |
Current Penalty |
1885.0 |
Initial Penalty |
1885.0 |
Final Order |
2018-04-10 |
Nr Instances |
2 |
Nr Exposed |
4 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.134(h)(2)(i): Respirators were not stored to protect them from damage, contamination, dust, sunlight, extreme temperatures, excessive moisture, and damaging chemicals or were not packed or stored to prevent deformation of the face piece and exhalation valve. Coastal Dock, F/V Alaska Mist, Reefer and Gear Rooms: On or about 05 February 2018 and times prior thereto, Respirators were not properly stored for protection. This exposed employees to respiratory hazards. |
|
|
340409549
|
1032100
|
2015-02-04
|
F/V ALASKA MIST COASTAL DOCK, DUTCH HARBOR, AK, 99692
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2015-02-04
|
Emphasis |
L: FISH, P: FISH
|
Case Closed |
2015-05-11
|
Related Activity
Type |
Inspection |
Activity Nr |
1041834 |
Health |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
5A0001 |
Issuance Date |
2015-03-16 |
Abatement Due Date |
2015-04-13 |
Current Penalty |
1400.0 |
Initial Penalty |
2000.0 |
Final Order |
2015-04-10 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees. F/V Alaska Mist, Machine shop area, Coastal Dock: On or about 4 February 2015 and times prior thereto the Blue Miller 180 welder was improperly wired to a 208 volt power cord. This condition exposed employees to an electrical shock and burn hazard. |
|
Citation ID |
01002A |
Citaton Type |
Serious |
Standard Cited |
19150089 B |
Issuance Date |
2015-03-16 |
Abatement Due Date |
2015-04-13 |
Current Penalty |
1960.0 |
Initial Penalty |
2800.0 |
Final Order |
2015-04-10 |
Nr Instances |
1 |
Nr Exposed |
15 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1915.89(b): The employers program did not cover procedures for lockout/tags-plus systems while servicing machinery, equipment, or systems. F/V Alaska Mist, Coastal Dock: On or about 4 February 2015 and times prior thereto, the Ship's lockout program did not address lockout/tags-plus process. This condition exposed employees to an amputation hazard. |
|
Citation ID |
01002B |
Citaton Type |
Serious |
Standard Cited |
19150089 C01 |
Issuance Date |
2015-03-16 |
Abatement Due Date |
2015-04-13 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2015-04-10 |
Nr Instances |
2 |
Nr Exposed |
20 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1915.89(c)(1): The employer did not ensure the use of a lock to prevent energization or startup, or the release of hazardous energy, before any servicing was started. F/V Alaska Mist, Coastal Dock, Factory Deck: On or about 4 February 2015 and times prior thereto, the Ryan 226 and Baader 415 Header machines had their cutting saws removed and were not locked out. This condition exposed employees to an amputation hazard. |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19180035 |
Issuance Date |
2015-03-16 |
Abatement Due Date |
2015-04-13 |
Current Penalty |
1400.0 |
Initial Penalty |
2000.0 |
Final Order |
2015-04-10 |
Nr Instances |
1 |
Nr Exposed |
15 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1918.35: Employees were working around open weather deck hatches which were not protected by coamings to a height of 24 inches (0.61 m), or by taut lines or barricades at a height of 36 to 42 inches (0.91 m to 1.07 m) above the deck. (a) F/V Alaska Mist, Factory Deck Area, Coastal Dock: On or about 4 February 2015 and times prior thereto, the rope railing was not taunt and had slack. This condition exposed employees to an eight foot fall hazard. (a) F/V Alaska Mist, Coastal dock, Engineering deck area: On or about 4 February 2014 and times prior thereto, the 30" X 36" hatchway was opened and not guarded. This condition exposed employees to a 103" fall hazard. |
|
Citation ID |
01004 |
Citaton Type |
Serious |
Standard Cited |
19180064 A |
Issuance Date |
2015-03-16 |
Abatement Due Date |
2015-04-13 |
Current Penalty |
840.0 |
Initial Penalty |
1200.0 |
Final Order |
2015-04-10 |
Nr Instances |
1 |
Nr Exposed |
10 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1918.64(a): Readily accessible stop controls were not provided on powered conveyors for use in an emergency. F/V Alaska Mist, Coastal Dock, freezer hold area: On or about 4 February 2015 and times prior thereto, the conveyor belt system was not equipped with a emergency stop. this condition exposed employees to an caught in hazard. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19180066 A06 |
Issuance Date |
2015-03-16 |
Abatement Due Date |
2015-04-13 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2015-04-10 |
Nr Instances |
1 |
Nr Exposed |
2 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1918.66(a)(6): When the rated load varies with the boom radius, the crane or derrick was not fitted with a boom angle or radius indicator visible to the operator. F/V Alaska Mist, Weather deck, Coastal dock: On about 4 February 2015 and times prior thereto, the Boom angle indicator was unreadable on the Blue Pedestal crane on the forward deck. This condition exposed employees to a struck by hazard. |
|
|
340418342
|
1032100
|
2015-02-04
|
F/V ALASKA MIST COASTAL DOCK, DUTCH HARBOR, AK, 99692
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Health
|
Close Conference |
2015-02-04
|
Emphasis |
L: FISH, P: FISH
|
Case Closed |
2015-05-11
|
Related Activity
Type |
Inspection |
Activity Nr |
1040954 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100095 D01 |
Issuance Date |
2015-03-16 |
Abatement Due Date |
2015-04-13 |
Current Penalty |
1680.0 |
Initial Penalty |
2400.0 |
Final Order |
2015-04-10 |
Nr Instances |
1 |
Nr Exposed |
5 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.95(d)(1): When information indicated that any employee's exposure equaled or exceed the 8-hour time-weighted average of 85 decibels, the employer did not develop and implement a monitoring program: a) F/V Alaska Mist, Factory, Deck, and Engine Spaces: On or about 2/4/2015, and times prior thereto, hearing conservation monitoring had not been completed for the vessel. This condition allowed for employees to not have the knowledge of noise hazardous conditions and where to wear hearing protection on the vessel. |
|
Citation ID |
01002A |
Citaton Type |
Serious |
Standard Cited |
19100133 A01 |
Issuance Date |
2015-03-16 |
Abatement Due Date |
2015-04-06 |
Current Penalty |
1120.0 |
Initial Penalty |
1600.0 |
Final Order |
2015-04-10 |
Nr Instances |
1 |
Nr Exposed |
4 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.133(a)(1): Protective eye equipment was not required where there was a reasonable probability of injury that could be prevented by such equipment: (a) Factory: On or about February 4, 2015 and times prior thereto, employees were cleaning with Santi 75 and Super Red Plus without wearing eye protection. This exposed employees to eye injuries from using a corrosive cleaner without any protection. |
|
Citation ID |
01002B |
Citaton Type |
Serious |
Standard Cited |
19100138 A |
Issuance Date |
2015-03-16 |
Abatement Due Date |
2015-04-06 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2015-04-10 |
Nr Instances |
1 |
Nr Exposed |
5 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.138(a): The employer did not select and require employee(s) to use appropriate hand protection when employees' hands were exposed to hazards such as those from skin absorption of harmful substances; severe cuts or lacerations; severe abrasion; punctures; chemical burns; thermal burns; and harmful temperature extremes. (a) Factory: On or about February 4, 2015 and times prior thereto, employees were not using gloves while using a corrosive chemical. This exposed employees to skin absorption of chemicals and chemical burn hazard from not protecting their skin. |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19100242 B |
Issuance Date |
2015-03-16 |
Abatement Due Date |
2015-04-06 |
Current Penalty |
1120.0 |
Initial Penalty |
1600.0 |
Final Order |
2015-04-10 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i. (a) Reefer Shop: On or about February 4, 2015 and times prior thereto, an air nozzle used for cleaning was operating at 90 p.s.i. This exposed employees to laceration/air embolism hazard from using an air nozzle that would not reduce if dead-ended with skin. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19101200 F06 I |
Issuance Date |
2015-03-16 |
Abatement Due Date |
2015-04-06 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2015-04-10 |
Nr Instances |
3 |
Nr Exposed |
22 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(f)(6)(i): Except as provided in 29 CFR 1910.1200(f)(7) and 29 CFR 1910.1200(f)(8), the employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the information required by 29 CFR 1910.1200(f)(1)(i) through 29 CFR 1910.1200(f)(1)(v): (a) Reefer Shop: On or about 2/4/2015, and times prior thereto, there was an unlabeled container in the work area. This exposed employees to delays in getting proper first aid and knowing the correct PPE for the type of chemical. |
|
Citation ID |
02002 |
Citaton Type |
Other |
Standard Cited |
19101200 H03 |
Issuance Date |
2015-03-16 |
Abatement Due Date |
2015-04-06 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2015-04-10 |
Nr Instances |
1 |
Nr Exposed |
20 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(h)(3): The employee training did not include the requirements of 29 CFR 1910.1200(h)(3)(i) through (h)(3)(iv): (a) Vessel employees: On or about February 4, 2015 and times prior thereto, employees had not been trained on the requirements of the Global Harmonization System. The lack of training would limit their ability to understand the new requirements of the program. |
|
|
331918722
|
1032100
|
2012-02-12
|
F/V ALASKA MIST, DUTCH HARBOR, AK, 99692
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Health
|
Close Conference |
2012-02-12
|
Emphasis |
L: FISH, N: AMPUTATE
|
Case Closed |
2012-05-09
|
Related Activity
Type |
Inspection |
Activity Nr |
191874 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100023 A07 |
Issuance Date |
2012-03-09 |
Abatement Due Date |
2012-04-06 |
Current Penalty |
1512.0 |
Initial Penalty |
2160.0 |
Final Order |
2012-03-30 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.23(a)(7): Every temporary floor opening did not have standard railings, or was not constantly attended by someone: Factory Deck: On or about February 12, 2012, and at times prior thereto, the freezer hatch was guarded by a single rope "rail" place at a height of 40 inches. This condition exposed employees to a height of 11 feet. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100133 A01 |
Issuance Date |
2012-03-09 |
Abatement Due Date |
2012-04-06 |
Current Penalty |
2268.0 |
Initial Penalty |
3240.0 |
Final Order |
2012-03-30 |
Nr Instances |
1 |
Nr Exposed |
10 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.133(a)(1): The employer did not ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation: Factory Deck: On or about February 12, 2012 and at times prior thereto, employees were not provided with chemical splash goggles when using the cleaner "Super Red Hot." This condition exposed employees to eye hazards from the corrosive liquid. |
|
|
331918748
|
1032100
|
2012-02-12
|
F/V ALASKA MIST, DUTCH HARBOR, AK, 99692
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2012-02-12
|
Emphasis |
L: FISH, N: AMPUTATE
|
Case Closed |
2012-05-09
|
Related Activity
Type |
Inspection |
Activity Nr |
191872 |
Health |
Yes |
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19100215 B09 |
Issuance Date |
2012-03-09 |
Abatement Due Date |
2012-04-06 |
Current Penalty |
1512.0 |
Initial Penalty |
2160.0 |
Final Order |
2012-05-09 |
Nr Instances |
2 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.215(b)(9): Exposure adjustment. Safety guards of the types described in Subparagraphs (3) and (4) of this paragraph, where the operator stands in front of the opening, shall be constructed so that the peripheral protecting member can be adjusted to the constantly decreasing diameter of the wheel. The maximum angular exposure above the horizontal plane of the wheel spindle as specified in paragraphs(b)(3) and (4) of this section shall never be exceeded, and the distance between the wheel periphery and the adjustable tongue or the end of the peripheral member at the top shall never exceed one-fourth inch. (a) F/V Alaska Mist (Machine Shop): On or about 2/12/2012, and times prior thereto, the Dayton Bench grinder did not have a tongue guard; exposing employees to struck by hazards in the event of wheel failure. (b) F/V Alaska Mist (Reefer Flat): On or about 2/12/2012, and times prior thereto, the Dayton Bench grinder did not have a tongue guard; exposing employees to struck by hazards in the event of wheel failure. |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19150134 B |
Issuance Date |
2012-03-09 |
Abatement Due Date |
2012-04-06 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Nr Instances |
2 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1915.134(b): Floor and bench mounted grinders shall be provided with work rests which are rigidly supported and readily adjustable. Such work rests shall be kept a distance not to exceed 1/8 inch from the surface of the wheel. (a) F/V Alaska Mist (Machine Shop): On or about 2/12/2012, and times prior thereto, the Dayton Bench grinder work rest measured 1/4 inch; exposing employees to struck by hazards in the event of wheel failure. (b) F/V Alaska Mist (Reefer Flat): On or about 2/12/2012, and times prior thereto, the Dayton Bench grinder work rest measured 1/4 inch; exposing employees to struck by hazards in the event of wheel failure. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100242 B |
Issuance Date |
2012-03-09 |
Abatement Due Date |
2012-04-06 |
Current Penalty |
1134.0 |
Initial Penalty |
1620.0 |
Final Order |
2012-05-09 |
Nr Exposed |
2 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.242(b): Compressed air used for cleaning. Compressed air shall not be used for cleaning purposes except where reduced to less than 30 p.s.i. and then only with effective chip guarding and personal protective equipment. F/V Alaska Mist (Machine Shop): On or about 2/12/2012, and times prior thereto, an air nozzle was being used at 200 psi for cleaning purposes that did not have a pressure reduction device attached; exposing employees to laceration or embolism hazards. |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19150056 B02 |
Issuance Date |
2012-03-09 |
Abatement Due Date |
2012-04-06 |
Current Penalty |
1512.0 |
Initial Penalty |
2160.0 |
Final Order |
2012-05-09 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1915.56(b)(2): Only cable free from repair or splices for a minimum distance of ten (10) feet from the cable end to which the electrode holder is connected shall be used, except that cables with standard insulated connectors or with splices whose insulating quality is equal to that of the cable are permitted. F/V Alaska Mist (Reefer Flat Area): A welding lead was available for use which had been damaged within 10 feet of the electrode holder; exposing employees to electrical hazards. |
|
Citation ID |
01004 |
Citaton Type |
Serious |
Standard Cited |
19180062 A02 |
Issuance Date |
2012-03-09 |
Abatement Due Date |
2012-03-23 |
Current Penalty |
963.9 |
Initial Penalty |
1377.0 |
Final Order |
2012-05-09 |
Nr Instances |
1 |
Nr Exposed |
4 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1918.62(a)(2): Defective gear, as defined by the manufacturers' specifications (when available), shall not be used. Distorted hooks, shackles or similar gear shall be discarded. Weather Deck: On or about February 13, and times prior thereto, brailer bags were used with cuts and snags on the bag and lifting legs. This exposed employees to struck-by hazards from defective gear failing during offloads of up to 2000 ilbs of fish. |
|
|