343530986
|
1032100
|
2018-10-11
|
405 WEST 36TH AVENUE SUITE 210, ANCHORAGE, AK, 99503
|
|
Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Health
|
Close Conference |
2018-10-11
|
Emphasis |
L: FISH, L: SHIP
|
Case Closed |
2019-02-05
|
Related Activity
Type |
Referral |
Activity Nr |
1389618 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Other |
Standard Cited |
19150089 G01 |
Issuance Date |
2018-12-20 |
Abatement Due Date |
2019-02-05 |
Current Penalty |
5174.0 |
Initial Penalty |
5174.0 |
Final Order |
2019-01-15 |
Nr Instances |
1 |
Nr Exposed |
2 |
Related Event Code (REC) |
Referral |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1915.89(g)(1): The employer did not ensure that the authorized employee, or the primary authorized employee in a group lockout/tags-plus application, continues verifying deenergization and isolation while servicing the machinery, equipment, or system: F/V Aleutian Sable: On September 4, 2018, the employer did not verify continuing deenegization and isolation during maintenance of the ammonia refrigeration system. This condition exposed employees to inhalation and skin burns from anhydrous ammonia and resulted in in-patient hospitalization and follow-up care. |
|
Citation ID |
01001B |
Citaton Type |
Other |
Standard Cited |
19150089 P02 |
Issuance Date |
2018-12-20 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2019-01-15 |
Nr Instances |
1 |
Nr Exposed |
2 |
Related Event Code (REC) |
Referral |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1915.89(p)(2): The employer did not promptly but not later than 24 hours following the incident, initiate an incident investigation and notify each employee who was, or could reasonably have been, affected by the incident. F/V Aleutian Sable: On September 5, 2018, the employer had not initiated an incident investigation and notify each employee on its results. This condition limited employee information regarding the failure of the lockout/tags plus program and mechanical systems involved in the failure and continues to expose employees to inhalation and skin burns from anhydrous ammonia. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19040007 B05 |
Issuance Date |
2018-12-20 |
Abatement Due Date |
2019-01-10 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2019-01-15 |
Nr Instances |
1 |
Nr Exposed |
12 |
Related Event Code (REC) |
Referral |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1904.7(b)(5): A work-related injury or illness resulting in medical treatment beyond first aid was not recorded on the OSHA 300 log: F/V Aleutian Sable: By September 11, 2018, a work-related injury resulting in medical treatment beyond first aid including the administration of prescription medications was not recorded on the 2018 OSHA 300. This condition limited employee information regarding the nature and extent of a work-related injury. |
|
Citation ID |
02002 |
Citaton Type |
Other |
Standard Cited |
19040039 A02 |
Issuance Date |
2018-12-20 |
Abatement Due Date |
2019-01-10 |
Current Penalty |
2042.0 |
Initial Penalty |
3141.0 |
Final Order |
2019-01-15 |
Nr Instances |
1 |
Nr Exposed |
1 |
Related Event Code (REC) |
Referral |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1904.39(a)(2): The employer did not report within 24-hours a work-related incident resulting in in-patient hospitalization, amputation or the loss of an eye: F/V Aleutian Sable: On September 5, 2018, the employer did not report an in-patient hospitalization. This condition limited the opportunity to properly investigate the circumstance(s) of the work-related injury. |
|
Citation ID |
02003 |
Citaton Type |
Other |
Standard Cited |
19100120 Q01 |
Issuance Date |
2018-12-20 |
Abatement Due Date |
2019-02-05 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2019-01-15 |
Nr Instances |
1 |
Nr Exposed |
4 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.120(q)(1): The employer did not develop and implement an emergency response plan to handle anticipated emergencies prior to commencement of emergency response operations: F/V Aleutian Sable: On or about September 5, 2018 and at times prior thereto, the employer had not developed and implemented an emergency response plan for anticipated ammonia releases. This condition exposed employee to inhalation hazards. |
|
|
342941739
|
1032100
|
2018-02-08
|
F/V ALEUTIAN SABLE RESOFF DOCK, DUTCH HARBOR, AK, 99692
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2018-02-08
|
Emphasis |
L: FISH, P: FISH
|
Case Closed |
2018-04-23
|
Related Activity
Type |
Inspection |
Activity Nr |
1294180 |
Health |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100037 A04 |
Issuance Date |
2018-03-14 |
Abatement Due Date |
2018-04-11 |
Current Penalty |
3696.0 |
Initial Penalty |
3696.0 |
Final Order |
2018-04-06 |
Nr Instances |
1 |
Nr Exposed |
12 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.37(a)(4): Safeguard(s) designed to protect employees during an emergency (e.g., sprinkler systems, alarm systems, fire doors, exit lighting), were not in proper working order at all times. F/V Aleutian Sable, Resoff Dock, walk-in freezer; on or about 08 February 2018 and time prior thereto; the employer did not ensure that safety features were in proper working order at all times. The emergency escape plunger on the walk-in freezer was missing the internal plunger element. This condition exposed employees to a caught in hazard. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19150132 D |
Issuance Date |
2018-03-14 |
Current Penalty |
2217.0 |
Initial Penalty |
2217.0 |
Final Order |
2018-04-06 |
Nr Instances |
1 |
Nr Exposed |
12 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1915.132(d): Worn or frayed electric cables shall not be used. F/V Aleutian Sable, Resoff Dock, Deck Port side, on or about 08 February 2018 and time prior thereto; A Skilsaw brand 7 1/4-inch Worm Drive Saw, Model HD77M, Serial Number H18327, had damage to the outer protective jacket. This condition exposed employees to an electrical shock hazard. |
|
Citation ID |
02001 |
Citaton Type |
Repeat |
Standard Cited |
19040032 A04 |
Issuance Date |
2018-03-14 |
Abatement Due Date |
2018-04-11 |
Current Penalty |
1478.0 |
Initial Penalty |
1478.0 |
Final Order |
2018-04-06 |
Nr Instances |
1 |
Nr Exposed |
12 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1904.32(a)(4): The employer did not post an OSHA 300A Form or equivalent by February 1 thru April 30. F/V Aleutian Sable; on or about 08 February 2018 and time prior thereto; the OSHA Form 300A for the calendar year 2017 was not post. This condition leads to inaccurate reporting of injuries and illnesses. Arctic Sablefish LLC., was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1904.32(a)(4) which was contained in OSHA inspection number 1041845, citation number 2, item number 2 and was affirmed as a final order on 04 May 2015, with respect to a workplace located at Coastal Dock in Dutch Harbor, AK. |
|
Citation ID |
03001 |
Citaton Type |
Other |
Standard Cited |
19150089 Q01 |
Issuance Date |
2018-03-14 |
Abatement Due Date |
2018-04-11 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2018-04-06 |
Nr Instances |
1 |
Nr Exposed |
12 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1915.89(q)(1): The employer did not ensure that the audit was performed by an authorized employee other than the one(s) currently using the energy-control procedure being reviewed. F/V Aleutian Sable, Resoff dock, engine room, on or about 08 February 2018 and times prior thereto; the employer did not ensure that the annual audit of the lockout/tags plus program and procedure was completed. This condition exposed employees to unsafe work practices. |
|
|
342941804
|
1032100
|
2018-02-08
|
F/V ALEUTIAN SABLE CITY DOCK, DUTCH HARBOR, AK, 99692
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Health
|
Close Conference |
2018-02-08
|
Emphasis |
P: FISH, L: FISH
|
Case Closed |
2018-04-25
|
Related Activity
Type |
Inspection |
Activity Nr |
1294173 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Repeat |
Standard Cited |
19100151 C |
Issuance Date |
2018-03-14 |
Abatement Due Date |
2018-04-11 |
Current Penalty |
4434.0 |
Initial Penalty |
4434.0 |
Final Order |
2018-04-06 |
Nr Instances |
1 |
Nr Exposed |
10 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use Resoft Dock, F/V Aleutian Sable, Factory: On or about 08 February 2018 and times prior thereto, there were no facilities for employees to rinse their eyes immediately if they got a corrosive chemical in their eyes. This exposed employees to chemical burn to the eyes. The F/V Aleutian Sable was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.151(c), which was contained in OSHA inspection number 1041845, citation number 1, item number 2 and was affirmed as a final order on 04 May 2014, with respect to a workplace located on F/V Aleutian Sable. |
|
Citation ID |
01002 |
Citaton Type |
Repeat |
Standard Cited |
19101200 F06 I |
Issuance Date |
2018-03-14 |
Abatement Due Date |
2018-04-11 |
Current Penalty |
207.0 |
Initial Penalty |
207.0 |
Final Order |
2018-04-06 |
Nr Instances |
1 |
Nr Exposed |
12 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(f)(6)(i): Except as provided in 29 CFR 1910.1200(f)(7) and 29 CFR 1910.1200(f)(8), the employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the information required by 29 CFR 1910.1200(f)(1)(i) through 29 CFR 1910.1200(f)(1)(v) Resoft Dock, F/V Aleutian Sable, Companionway: On or about 08 February 2018, and times prior thereto, there was unlabeled container in the work area. This exposed employees to delays in getting proper first aid and knowing the correct PPE for the type of chemical. The F/V Aleutian Sable was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1910.1200(f)(6)(I), which was contained in OSHA inspection number 1041845, citation number 1, item number 8C and was affirmed as a final order on 04 May 2015 with respect to a workplace located on F/V Aleutian Sable. |
|
|
340418458
|
1032100
|
2015-02-06
|
F/V ALEUTIAN SABLE COASTAL DOCK, DUTCH HARBOR, AK, 99692
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Health
|
Close Conference |
2015-02-06
|
Emphasis |
L: FISH, P: FISH
|
Case Closed |
2015-07-24
|
Related Activity
Type |
Inspection |
Activity Nr |
1041275 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100095 D01 |
Issuance Date |
2015-03-27 |
Abatement Due Date |
2015-07-24 |
Current Penalty |
1100.0 |
Initial Penalty |
2200.0 |
Final Order |
2015-05-04 |
Nr Instances |
1 |
Nr Exposed |
5 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.95(d)(1): When information indicated that any employee's exposure equaled or exceed the 8-hour time-weighted average of 85 decibels, the employer did not develop and implement a monitoring program: F/V Aleutian Sable, Coastal Dock, Engine Room: On or about 2/6/2015, and times prior thereto, employees working in the engine and other high noise areas were exposed to noise at between 97.5 dB(A) and 105 dB(A) for 8 hours. None of the employees received hearing exams for exposure to noise. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100151 C |
Issuance Date |
2015-03-27 |
Abatement Due Date |
2015-07-24 |
Current Penalty |
1320.0 |
Initial Penalty |
2640.0 |
Final Order |
2015-05-04 |
Nr Instances |
1 |
Nr Exposed |
5 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.151(c): Where the eyes or body of any person may be exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body shall be provided within the work area for immediate emergency use. F/V Aleutian Sable, Coastal Dock, Factory: On or about February 6, 2015 and times prior thereto, there was no facilities for employees to rinse their eyes immediately if they got a corrosive chemical in their eyes. This exposed employees to chemical burn to the eyes. |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19100212 A05 |
Issuance Date |
2015-03-27 |
Abatement Due Date |
2015-07-24 |
Current Penalty |
880.0 |
Initial Penalty |
1760.0 |
Final Order |
2015-05-04 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.212(a)(5): Fan blade guard(s) were not provided where the periphery of the blades was less than seven feet from the floor or working level: F/V Aleutian Sable, Coastal Dock, Factory: On or about February 6 and times prior thereto, fan was not properly guarded. This exposed employees to laceration/amputation to the hands from incidental contact with the blade. |
|
Citation ID |
01004A |
Citaton Type |
Serious |
Standard Cited |
19100215 A04 |
Issuance Date |
2015-03-27 |
Abatement Due Date |
2015-07-24 |
Current Penalty |
880.0 |
Initial Penalty |
1760.0 |
Final Order |
2015-05-04 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.215(a)(4): Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one eighth inch: F/V Aleutian Sable, Coastal Dock, Maintenance shop: On or about February 6, 2015 and times prior thereto, the work rest measured at 1/4 inch. This exposed employees to struck-by hazard from work piece getting stuck between rest and wheel causing wheel to break. |
|
Citation ID |
01004B |
Citaton Type |
Serious |
Standard Cited |
19100215 B09 |
Issuance Date |
2015-03-27 |
Abatement Due Date |
2015-07-24 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2015-05-04 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch: F/V Aleutian Sable, Coastal Dock, Maintenance shop: On or about February 5, 2015 and times prior thereto, the tongue measured at 1 inch. This exposed employees to struck-by hazard if the wheel broke. |
|
Citation ID |
01005 |
Citaton Type |
Serious |
Standard Cited |
19100242 B |
Issuance Date |
2015-03-27 |
Abatement Due Date |
2015-07-24 |
Current Penalty |
880.0 |
Initial Penalty |
1760.0 |
Final Order |
2015-05-04 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.I. F/V Aleutian Sable, Coastal Dock, Maintenance Shop: On or about February 4, 2015 and times prior thereto, an air nozzle used for cleaning was operating at 90 p.s.i. This exposed employees to laceration/air embolism hazard from using an air nozzle that would not reduce if dead-ended with skin. |
|
Citation ID |
01006 |
Citaton Type |
Serious |
Standard Cited |
19100253 B04 I |
Issuance Date |
2015-03-27 |
Abatement Due Date |
2015-07-24 |
Current Penalty |
880.0 |
Initial Penalty |
1760.0 |
Final Order |
2015-05-04 |
Nr Instances |
1 |
Nr Exposed |
20 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.253(b)(4)(i): Oxygen cylinders were stored near highly combustible material, especially oil and grease; or near reserve stocks of carbide and acetylene or other fuel-gas cylinders, or near other substance likely to cause or accelerate fire. F/V Aleutian Sable, Coastal Dock, Bow storage area: On or about February 5, 2015 and times prior thereto, oxygen and acetylene cylinders were stored together. This exposed employees to accelerated smoke inhalation and fire hazard in the event of a fire. |
|
Citation ID |
01007 |
Citaton Type |
Serious |
Standard Cited |
19101030 C01 I |
Issuance Date |
2015-03-27 |
Abatement Due Date |
2015-07-24 |
Current Penalty |
1100.0 |
Initial Penalty |
2200.0 |
Final Order |
2015-05-04 |
Nr Instances |
1 |
Nr Exposed |
12 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1030(c)(1)(i): The employer having employee(s) with occupational exposure did not establish a written Exposure Control Plan designed to eliminate or minimize employee exposure: F/V Aleutian Sable, Coastal Dock, Vessel: On or about 2/06/2014 and times prior thereto, the employer did establish a written exposure control plan for Blood borne pathogens. This condition exposed employees to Blood Borne Pathogen and infections. |
|
Citation ID |
01008A |
Citaton Type |
Serious |
Standard Cited |
19101200 E01 |
Issuance Date |
2015-03-27 |
Abatement Due Date |
2015-07-24 |
Current Penalty |
1100.0 |
Initial Penalty |
2200.0 |
Final Order |
2015-05-04 |
Nr Instances |
2 |
Nr Exposed |
12 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: F/V Aleutian Sable: On or about 2/6/2015, and times prior thereto, the employer did not have a written hazard communication program implemented that demonstrated how to safely handle workplace chemicals. This exposed employees to delays in getting proper first aid and knowing the correct PPE for the type of chemical. |
|
Citation ID |
01008B |
Citaton Type |
Serious |
Standard Cited |
19101200 H03 |
Issuance Date |
2015-03-27 |
Abatement Due Date |
2015-07-24 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2015-05-04 |
Nr Instances |
1 |
Nr Exposed |
12 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(h)(3): The employee training did not include the requirements of 29 CFR 1910.1200(h)(3)(i) through (h)(3)(iv): F/V Aleutian Sable, Coastal Dock: On or about February 6, 2015 and times prior thereto, employees had not been trained on the requirements of the Global Harmonization System. The lack of training would limit their ability to understand the new requirements of the program. |
|
Citation ID |
01008C |
Citaton Type |
Serious |
Standard Cited |
19101200 F06 I |
Issuance Date |
2015-03-27 |
Abatement Due Date |
2015-07-24 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2015-05-04 |
Nr Instances |
2 |
Nr Exposed |
12 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(f)(6)(i): Except as provided in 29 CFR 1910.1200(f)(7) and 29 CFR 1910.1200(f)(8), the employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the information required by 29 CFR 1910.1200(f)(1)(i) through 29 CFR 1910.1200(f)(1)(v): F/V Aleutian Sable: On or about 2/6/2015, and times prior thereto, the employer did not have labels affixed to chemicals such as Super Red, Super Clean, among other chemicals used in the factory and for maintenance activities; exposing employees to chemical hazards. |
|
Citation ID |
01009 |
Citaton Type |
Serious |
Standard Cited |
19150056 B04 |
Issuance Date |
2015-03-27 |
Abatement Due Date |
2015-07-24 |
Current Penalty |
880.0 |
Initial Penalty |
1760.0 |
Final Order |
2015-05-04 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1915.56(b)(4): Welding cable in poor condition was used. F/V Aleutian Sable, Coastal Dock, Weather deck: On or about February 6, 2015 and times prior thereto, a welding cable was used that was cut to the conductor. This exposed employees to shock/burn hazard from incidental contact with conductor while welding. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19040004 A |
Issuance Date |
2015-03-27 |
Abatement Due Date |
2015-07-24 |
Current Penalty |
220.0 |
Initial Penalty |
440.0 |
Final Order |
2015-05-04 |
Nr Instances |
1 |
Nr Exposed |
20 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1904.4(a): The employer did not record each work-related fatality, injury or illness case that resulted in the general recording criteria on the OSHA Form 300 or equivalent. F/V Aleutian Sable, Coastal Dock, Vessel: On or about February 6, 2015 and times prior thereto, the employer was not recording employee injuries on the OSHA 300 or equivalent. Abatement Certification and Documentation is required |
|
Citation ID |
02002 |
Citaton Type |
Other |
Standard Cited |
19040032 A04 |
Issuance Date |
2015-03-27 |
Abatement Due Date |
2015-07-24 |
Current Penalty |
220.0 |
Initial Penalty |
440.0 |
Final Order |
2015-05-04 |
Nr Instances |
1 |
Nr Exposed |
12 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1904.32(a)(4): The employer did not post an OSHA 300A Form or equivalent by February 1 thru April 30. F/V Aleutian Sable, Coastal Dock, Vessel: On or about 2/06/2015 and times prior thereto the employer failed to post the annual summary of work-related injuries and illnesses for Calendar year 2014. |
|
|
340412758
|
1032100
|
2015-02-06
|
F/V ALEUTIAN SABLE COASTAL DOCK, DUTCH HARBOR, AK, 99692
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2015-02-06
|
Emphasis |
L: FISH, P: FISH
|
Case Closed |
2015-05-15
|
Related Activity
Type |
Inspection |
Activity Nr |
1041845 |
Health |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
5A0001 |
Issuance Date |
2015-03-27 |
Abatement Due Date |
2015-04-24 |
Current Penalty |
1540.0 |
Initial Penalty |
3080.0 |
Final Order |
2015-05-04 |
Nr Instances |
4 |
Nr Exposed |
12 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees. F/V Aleutian Sable, Coastal Dock; on or about 6 February 2015, and times prior thereto; four (4) instances were noted where electrical hazards existed: (a) Bow Storage area: a 208 volt electrical panel was missing a cover and dead front. (b) Bow storage area; a 100 foot yellow/blue extension cord cut insulation and wiring taped together with black electrical tape. (c) Wheel house stairs: a 120 volt light bulb was unguarded from damage and had exposed wiring. (d) Lower state rooms: a 50 foot orange extension cord was routed down the hallway and into a stateroom, through doorways. These conditions exposed employees to electrical shock and electrical burn hazards and electrocution. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19150073 G |
Issuance Date |
2015-03-27 |
Abatement Due Date |
2015-04-24 |
Current Penalty |
660.0 |
Initial Penalty |
1320.0 |
Final Order |
2015-05-04 |
Nr Instances |
1 |
Nr Exposed |
12 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1915.73(g): Gratings, walkways, and catwalks, from which sections or ladders have been removed, were not barricaded with adequate guardrails. Aleutian Sable, Coastal Dock, Weather deck; On or about 6 February 2015 and times prior thereto, a 6" by 48" deck planking was removed on the main deck. This condition exposed employees to a tripping hazard. |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19150081 A01 |
Issuance Date |
2015-03-27 |
Abatement Due Date |
2015-04-24 |
Current Penalty |
660.0 |
Initial Penalty |
1320.0 |
Final Order |
2015-05-04 |
Nr Instances |
1 |
Nr Exposed |
12 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1915.81(a)(1): The employer did not maintain good housekeeping practices to eliminate hazards to employees. F/V Aleutian Sable, Coastal Dock, Bow storage area: On or about 6 February 2015 and times prior thereto, equipment and supplies were stored impeding access to the forward electrical panels and also creating tripping hazards. This condition exposed employees to tripping hazards and delays in accessing electrical panels resulting in smoke inhalation. |
|
Citation ID |
01004A |
Citaton Type |
Serious |
Standard Cited |
19150089 B |
Issuance Date |
2015-03-27 |
Abatement Due Date |
2015-07-24 |
Current Penalty |
1540.0 |
Initial Penalty |
3080.0 |
Final Order |
2015-05-04 |
Nr Instances |
2 |
Nr Exposed |
12 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1915.89(b): The employers program did not cover procedures for lockout/tags-plus systems while servicing machinery, equipment, or systems. F/V Aleutian Sable, Coastal Dock: On or about 6 February 2015 and times prior thereto, a lockout/tags-plus program was not implemented on the vessel. This condition exposed employees to amputation hazards. |
|
Citation ID |
01004B |
Citaton Type |
Serious |
Standard Cited |
19150089 C01 |
Issuance Date |
2015-03-27 |
Abatement Due Date |
2015-07-24 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2015-05-04 |
Nr Instances |
2 |
Nr Exposed |
2 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1915.89(c)(1): The employer did not ensure the use of a lock to prevent energization or startup, or the release of hazardous energy, before any servicing was started. F/V Aleutian Sable, Coastal Dock, Factory Deck: On or about 4 February 2015 and times prior thereto, the Ryan and Baader 415 Header machines had their cutting saws removed and were not locked out. This condition exposed employees to an amputation hazard. |
|
Citation ID |
01005 |
Citaton Type |
Serious |
Standard Cited |
19150116 J |
Issuance Date |
2015-03-27 |
Current Penalty |
1540.0 |
Initial Penalty |
3080.0 |
Final Order |
2015-05-04 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1915.116(j): Loads were suspended over the heads of employees. F/V Aleutian Sable, Coastal Dock, Main deck area: On or about 6 February 205 and times prior thereto, cargo loads of approximately 2299 pounds of frozen fish were moved over employees on the main deck area. This condition exposed employees to a struck by hazard. |
|
Citation ID |
01006 |
Citaton Type |
Serious |
Standard Cited |
19180011 A |
Issuance Date |
2015-03-27 |
Abatement Due Date |
2015-07-24 |
Current Penalty |
1100.0 |
Initial Penalty |
2200.0 |
Final Order |
2015-05-04 |
Nr Instances |
1 |
Nr Exposed |
5 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1918.11(a): The employer used the vessel's cargo handling gear without ascertaining that the vessel had a current and valid cargo gear register and certificates in accordance with ILO 152 recommendations. F/V Aleutian Sable, Coastal dock, Main deck: On or about 6 February 2015 and times prior thereto, the vessel cargo crane did not have an annual marine crane certification accomplished. This condition exposed employees to a struck by hazard. |
|
Citation ID |
01007 |
Citaton Type |
Serious |
Standard Cited |
19180035 |
Issuance Date |
2015-03-27 |
Current Penalty |
1540.0 |
Initial Penalty |
3080.0 |
Final Order |
2015-05-04 |
Nr Instances |
4 |
Nr Exposed |
12 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1918.35: Employees were working around open weather deck hatches which were not protected by coamings to a height of 24 inches (0.61 m), or by taut lines or barricades at a height of 36 to 42 inches (0.91 m to 1.07 m) above the deck. (a) F/V Aleutian Sable, Coastal Dock, Weather deck: On or about 6 February 2015 and times prior thereto, the 91" x 91" hatch was open without railings installed. This condition exposed employees to a 118" fall hazard. (b) F/V Aleutian Sable, Coastal Dock, Aft deck: On or about 6 February 2015 and times prior thereto, the 20" x 24" hatch was open without railings installed. This condition exposed employees to a 91" fall hazard. (c) F/V Aleutian Sable, Coastal Dock, Main deck: On or about 6 February 2015 and times prior thereto, the 20" x 24" hatch was open without railings installed. This condition exposed employees to a 118" fall hazard. (d) F/V Aleutian Sable, Coastal Dock, Lower bow storage access ladder: On or about 6 February 2015 and times prior thereto, the 31" x 36" lower bow storage deck hatch was unguarded without railings installed. This condition exposed employees to a 91" fall hazard. |
|
Citation ID |
01008 |
Citaton Type |
Serious |
Standard Cited |
19180066 A06 |
Issuance Date |
2015-03-27 |
Abatement Due Date |
2015-07-24 |
Current Penalty |
1320.0 |
Initial Penalty |
2640.0 |
Final Order |
2015-05-04 |
Nr Instances |
1 |
Nr Exposed |
4 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1918.66(a)(6): When the rated load varies with the boom radius, the crane or derrick was not fitted with a boom angle or radius indicator visible to the operator. F/V Aleutian Sable, Weather deck, Coastal dock: On about 6 February 2015 and times prior thereto, the Boom angle indicator was unreadable on the Blue Pedestal crane on the forward deck. This condition exposed employees to a struck by hazard. |
|
|