338911795
|
1032100
|
2013-02-13
|
M/V COURAGEOUS COASTAL DOCK, DUTCH HARBOR, AK, 99692
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Health
|
Close Conference |
2013-02-13
|
Emphasis |
L: FISH, N: AMPUTATE, P: FISH
|
Case Closed |
2013-04-18
|
Related Activity
Type |
Inspection |
Activity Nr |
891182 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100132 D01 I |
Issuance Date |
2013-03-11 |
Current Penalty |
900.0 |
Initial Penalty |
1200.0 |
Final Order |
2013-03-27 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.132(d)(1)(i): The employer did not select and have each affected employee use, the types of personal protective equipment that would protect the affected employee(s) from the hazards identified in the hazard assessment: M/V Courageous (Galley): On or about 2/13/2013, the cook was not required to use cut resistant gloves while using knives in the galley for food preparation. This condition exposed the employee to laceration hazards. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19150089 E04 |
Issuance Date |
2013-03-11 |
Abatement Due Date |
2013-04-04 |
Current Penalty |
1800.0 |
Initial Penalty |
2400.0 |
Final Order |
2013-03-27 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1915.89(e)(4): The employer shall ensure that the authorized employee relieves, disconnects, restrains, or otherwise renders safe all potentially hazardous energy that is connected to the machinery, equipment, or system. M/V Courageous (Flow Scale): On or about 2/13/2013, and times prior thereto, an employee was working on the Flow Scale conveyor without ensuring that all energy sources were rendered safe by de-energizing and locking out the power to disconnects on the equipment; exposing employees to amputaion or caught in hazards. |
|
Citation ID |
02001 |
Citaton Type |
Repeat |
Standard Cited |
19100095 G06 |
Issuance Date |
2013-03-11 |
Abatement Due Date |
2013-04-30 |
Current Penalty |
4200.0 |
Initial Penalty |
5600.0 |
Final Order |
2013-03-27 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.95(g)(6): At least annually after obtaining the baseline audiogram, the employer did not obtain a new audiogram for each employee exposed at or above an 8-hour time-weighted average of 85 decibels : F/V Courageous (Engine room): On or about 2/13/2013, and times prior thereto, the employer did not conduct an annual audiogram for the engineer assistant; exposing the employee to the hazards of noise and potentual hearing loss. |
|
|
338911829
|
1032100
|
2013-02-13
|
M/V COURAGEOUS COASTAL DOCK, DUTCH HARBOR, AK, 99692
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2013-02-13
|
Emphasis |
L: FISH, P: FISH, N: AMPUTATE
|
Case Closed |
2013-04-05
|
Related Activity
Type |
Inspection |
Activity Nr |
891179 |
Health |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100037 A04 |
Issuance Date |
2013-03-11 |
Abatement Due Date |
2013-04-04 |
Current Penalty |
765.0 |
Initial Penalty |
1020.0 |
Final Order |
2013-03-27 |
Nr Instances |
1 |
Nr Exposed |
25 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.37(a)(4): Safeguard(s) designed to protect employees during an emergency (e.g., sprinkler systems, alarm systems, fire doors, exit lighting), were not in proper working order at all times. Galley and Upper deck area: On or about 13 February 2013 and times prior thereto, the emergency exit lighting for the galley and upper deck hallway area were inoperative. This exposed employees to delays in existing the vessel causing smoke inhalation and fire hazards. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19180064 A |
Issuance Date |
2013-03-11 |
Abatement Due Date |
2013-04-04 |
Current Penalty |
765.0 |
Initial Penalty |
1020.0 |
Final Order |
2013-03-27 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1918.64(a): Readily accessible stop controls were not provided on powered conveyors for use in an emergency. Freezer hold area during unloading operations on F/V Courageous: On or about 13 February 2013 and times prior thereto, the 110 volt electrically operated conveyor emergency stop was not accessible to in the hold area. This condition exposed employees to a struck by and caught in hazards. |
|
|
307505909
|
1032100
|
2010-02-06
|
F/V COURAGEOUS, DUTCH HARBOR, AK, 99692
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2010-02-06
|
Emphasis |
S: FALL FROM HEIGHT, L: FISH, S: STRUCK-BY
|
Case Closed |
2010-03-22
|
Related Activity
Type |
Inspection |
Activity Nr |
307505917 |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19180035 |
Issuance Date |
2010-02-19 |
Abatement Due Date |
2010-03-24 |
Current Penalty |
281.25 |
Initial Penalty |
375.0 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
03 |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19180043 A01 |
Issuance Date |
2010-02-19 |
Abatement Due Date |
2010-03-24 |
Current Penalty |
168.75 |
Initial Penalty |
225.0 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
01 |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19180024 I01 I |
Issuance Date |
2010-02-19 |
Abatement Due Date |
2010-03-24 |
Current Penalty |
112.5 |
Initial Penalty |
150.0 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
03 |
|
|
307505917
|
1032100
|
2010-02-06
|
F/V COURAGEOUS, DUTCH HARBOR, AK, 99692
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Health
|
Close Conference |
2010-02-06
|
Emphasis |
S: ELECTRICAL, L: FISH, S: FALL FROM HEIGHT, S: STRUCK-BY, S: NOISE
|
Case Closed |
2010-03-22
|
Related Activity
Type |
Inspection |
Activity Nr |
307505909 |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100095 G06 |
Issuance Date |
2010-02-18 |
Abatement Due Date |
2010-03-23 |
Current Penalty |
225.0 |
Initial Penalty |
300.0 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
02 |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19100242 B |
Issuance Date |
2010-02-19 |
Abatement Due Date |
2010-03-03 |
Current Penalty |
225.0 |
Initial Penalty |
300.0 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
02 |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19100253 B04 III |
Issuance Date |
2010-02-18 |
Abatement Due Date |
2010-03-08 |
Current Penalty |
225.0 |
Initial Penalty |
300.0 |
Nr Instances |
1 |
Nr Exposed |
24 |
Gravity |
02 |
|
Citation ID |
01004A |
Citaton Type |
Serious |
Standard Cited |
19101200 E01 |
Issuance Date |
2010-02-19 |
Abatement Due Date |
2010-03-24 |
Current Penalty |
168.75 |
Initial Penalty |
225.0 |
Nr Instances |
1 |
Nr Exposed |
24 |
Gravity |
01 |
|
Citation ID |
01004B |
Citaton Type |
Serious |
Standard Cited |
19101200 G01 |
Issuance Date |
2010-02-19 |
Abatement Due Date |
2010-03-24 |
Nr Instances |
1 |
Nr Exposed |
24 |
Gravity |
01 |
|
Citation ID |
01004C |
Citaton Type |
Serious |
Standard Cited |
19101200 H |
Issuance Date |
2010-02-19 |
Abatement Due Date |
2010-03-24 |
Nr Instances |
2 |
Nr Exposed |
24 |
Gravity |
01 |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19040032 A01 |
Issuance Date |
2010-02-19 |
Abatement Due Date |
2010-03-10 |
Current Penalty |
750.0 |
Initial Penalty |
1000.0 |
Nr Instances |
3 |
Gravity |
00 |
|
|
307499723
|
1032100
|
2006-01-24
|
M/V COURAGEOUS, DUTCH HARBOR, AK, 99692
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2006-01-24
|
Emphasis |
L: FISH
|
Case Closed |
2006-04-17
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19180025 C |
Issuance Date |
2006-02-23 |
Abatement Due Date |
2006-03-28 |
Current Penalty |
1125.0 |
Initial Penalty |
1500.0 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
10 |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19180034 |
Issuance Date |
2006-02-23 |
Abatement Due Date |
2006-03-28 |
Current Penalty |
337.5 |
Initial Penalty |
450.0 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
01 |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19180035 |
Issuance Date |
2006-02-23 |
Abatement Due Date |
2006-03-28 |
Current Penalty |
1125.0 |
Initial Penalty |
1500.0 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
10 |
|
Citation ID |
01004 |
Citaton Type |
Serious |
Standard Cited |
19180064 L02 |
Issuance Date |
2006-02-23 |
Abatement Due Date |
2006-03-28 |
Current Penalty |
787.5 |
Initial Penalty |
1050.0 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
05 |
|
|
307499756
|
1032100
|
2006-01-24
|
M/V COURAGEOUS, DUTCH HARBOR, AK, 99692
|
|
Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Health
|
Close Conference |
2006-01-24
|
Emphasis |
L: FISH
|
Case Closed |
2006-04-17
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19100023 A09 |
Issuance Date |
2006-02-23 |
Abatement Due Date |
2006-03-28 |
Current Penalty |
337.5 |
Initial Penalty |
450.0 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
01 |
|
Citation ID |
01002A |
Citaton Type |
Serious |
Standard Cited |
19100215 D01 |
Issuance Date |
2006-02-23 |
Abatement Due Date |
2006-03-28 |
Current Penalty |
562.5 |
Initial Penalty |
750.0 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
03 |
|
Citation ID |
01002B |
Citaton Type |
Serious |
Standard Cited |
19100215 D03 |
Issuance Date |
2006-02-23 |
Abatement Due Date |
2006-03-28 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
01 |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19180023 A |
Issuance Date |
2006-02-23 |
Abatement Due Date |
2006-03-28 |
Current Penalty |
562.5 |
Initial Penalty |
750.0 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
04 |
|
|